FireCADCalc

Draft Tube Efficiency and Pressure at the Runner Outlet

Pressure head at the draft tube inlet below the runner, draft tube efficiency and the margin above vapour pressure from velocities, setting height and losses.

Thermal power plant

Inputs

Examples: 6 to 1.5 m/s, inlet 3 m above tailrace, loss 10 %Kaplan 9 to 2 m/s, 4 m setting, loss 15 %, site at 600 mSubmerged setting -2 m, 7 to 1.8 m/s, loss 8 %

Accepted: 0.1 to 30 m/s
Accepted: 0.05 to 10 m/s
Accepted: -20 to 15 m
Accepted: 0 to 50 %
Accepted: 60 to 110 kPa
Accepted: 0.6 to 20 kPa
Accepted: 990 to 1,030 kg/m³

Results

Bernoulli between the draft tube inlet and the tailrace, the outlet at tailrace level. The setting height must also satisfy the Thoma cavitation criterion for the runner.

Velocity head recovered (ideal)2.3331m
Loss in the draft tube0.19986m
Absolute pressure head at the inlet10.199m
Absolute pressure at the inlet100.02kPa
Vacuum below atmospheric0.13325m
Margin above vapour pressure9.9604m
Draft tube efficiency85.388%

Download PDF CSV Link to this result Compare another case

Log in to save calculations to your dashboard.

Worked example

Example: 6 to 1.5 m/s, inlet 3 m above tailrace, loss 10 %. The inputs, in the units selected above:

InputValue
Velocity at the draft tube inlet6.0000 m/s
Velocity at the draft tube outlet1.5000 m/s
Height of the inlet above the tailrace3.0000 m
Draft tube loss as a share of the inlet velocity head10.000 %
Atmospheric pressure101.33 kPa
Vapour pressure of water2.3400 kPa
Water density1,000.0 kg/m³

Applying the formula below gives:

ResultValue
Velocity head recovered (ideal)1.7208 m
Loss in the draft tube0.18355 m
Absolute pressure head at the inlet5.7951 m
Absolute pressure at the inlet56.830 kPa
Vacuum below atmospheric4.5372 m
Margin above vapour pressure5.5564 m
Draft tube efficiency83.750 %

Open this example in the calculator and change any input.

Formula

\(\frac{p_2}{\rho g} = \frac{p_a}{\rho g} - H_s - \frac{V_2^2 - V_3^2}{2g} + h_f\)

\(\eta_d = \frac{\frac{V_2^2 - V_3^2}{2g} - h_f}{\frac{V_2^2}{2g}}\)

Variables

Symbol Meaning SI unit
\(V_2\) Velocity at the draft tube inlet m/s
\(V_3\) Velocity at the draft tube outlet m/s
\(H_s\) Height of the inlet above the tailrace m
\(k_d\) Draft tube loss as a share of the inlet velocity head -
\(p_a\) Atmospheric pressure Pa
\(p_v\) Vapour pressure of water Pa
\(\rho\) Water density kg/m³
\((V_2^2 - V_3^2)/2g\) Velocity head recovered (ideal) m
\(h_f\) Loss in the draft tube m
\(p_2/\rho g\) Absolute pressure head at the inlet m
\(p_2\) Absolute pressure at the inlet Pa
\((p_a - p_2)/\rho g\) Vacuum below atmospheric m
\((p_2 - p_v)/\rho g\) Margin above vapour pressure m
\(\eta_d\) Draft tube efficiency -

Method and standards

Energy equation through the draft tube.

Where it is used

  • Setting reaction turbines and checking draft tubes.
  • Exam calculations on draft tube efficiency.

Common mistakes

  • Forgetting the friction loss term.
  • Using gauge atmospheric pressure (zero) and then comparing with absolute vapour pressure.

Assumptions and limits

  • One-dimensional steady flow; outlet at tailrace level.

Questions and answers

What does the draft tube do?

It lets the turbine sit above the tailrace without losing that height, and recovers much of the runner's exit kinetic energy as a lower pressure (a suction) below the runner.

What limits the setting height?

Cavitation: the runner outlet pressure must stay well above vapour pressure; the Thoma coefficient of the runner sets the allowed height.

What do the defaults represent?

Runner exit velocity 6 m/s falling to 1.5 m/s at the outlet, the inlet 3 m above tailrace and a loss of 10 % of the inlet velocity head: 1.72 m of velocity head recovered, a pressure head of about 5.8 m absolute and 84 % draft tube efficiency.

Method and article reviewed by FireCAD engineering on 17 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.

Sources

Nag, Power Plant Engineering, 3rd ed. (Tata McGraw-Hill, 2008), ch. 10, sec. 10.8.7 (draft tubes)

Related calculators

Free engineering calculators: every page computes in SI and converts to your units. Results are for engineering estimation; verify critical designs against the referenced standards.

Rejoining the server...

Rejoin failed... trying again in seconds.

Failed to rejoin.
Please retry or reload the page.

The session has been paused by the server.

Failed to resume the session.
Please retry or reload the page.