Worked example
Example: 6 to 1.5 m/s, inlet 3 m above tailrace, loss 10 %. The inputs, in the units selected above:
| Input | Value |
|---|---|
| Velocity at the draft tube inlet | 6.0000 m/s |
| Velocity at the draft tube outlet | 1.5000 m/s |
| Height of the inlet above the tailrace | 3.0000 m |
| Draft tube loss as a share of the inlet velocity head | 10.000 % |
| Atmospheric pressure | 101.33 kPa |
| Vapour pressure of water | 2.3400 kPa |
| Water density | 1,000.0 kg/m³ |
Applying the formula below gives:
| Result | Value |
|---|---|
| Velocity head recovered (ideal) | 1.7208 m |
| Loss in the draft tube | 0.18355 m |
| Absolute pressure head at the inlet | 5.7951 m |
| Absolute pressure at the inlet | 56.830 kPa |
| Vacuum below atmospheric | 4.5372 m |
| Margin above vapour pressure | 5.5564 m |
| Draft tube efficiency | 83.750 % |
Open this example in the calculator and change any input.
Formula
\(\frac{p_2}{\rho g} = \frac{p_a}{\rho g} - H_s - \frac{V_2^2 - V_3^2}{2g} + h_f\)
\(\eta_d = \frac{\frac{V_2^2 - V_3^2}{2g} - h_f}{\frac{V_2^2}{2g}}\)
Variables
| Symbol | Meaning | SI unit |
|---|---|---|
| \(V_2\) | Velocity at the draft tube inlet | m/s |
| \(V_3\) | Velocity at the draft tube outlet | m/s |
| \(H_s\) | Height of the inlet above the tailrace | m |
| \(k_d\) | Draft tube loss as a share of the inlet velocity head | - |
| \(p_a\) | Atmospheric pressure | Pa |
| \(p_v\) | Vapour pressure of water | Pa |
| \(\rho\) | Water density | kg/m³ |
| \((V_2^2 - V_3^2)/2g\) | Velocity head recovered (ideal) | m |
| \(h_f\) | Loss in the draft tube | m |
| \(p_2/\rho g\) | Absolute pressure head at the inlet | m |
| \(p_2\) | Absolute pressure at the inlet | Pa |
| \((p_a - p_2)/\rho g\) | Vacuum below atmospheric | m |
| \((p_2 - p_v)/\rho g\) | Margin above vapour pressure | m |
| \(\eta_d\) | Draft tube efficiency | - |
Method and standards
Energy equation through the draft tube.
Where it is used
- Setting reaction turbines and checking draft tubes.
- Exam calculations on draft tube efficiency.
Common mistakes
- Forgetting the friction loss term.
- Using gauge atmospheric pressure (zero) and then comparing with absolute vapour pressure.
Assumptions and limits
- One-dimensional steady flow; outlet at tailrace level.
Questions and answers
What does the draft tube do?
It lets the turbine sit above the tailrace without losing that height, and recovers much of the runner's exit kinetic energy as a lower pressure (a suction) below the runner.
What limits the setting height?
Cavitation: the runner outlet pressure must stay well above vapour pressure; the Thoma coefficient of the runner sets the allowed height.
What do the defaults represent?
Runner exit velocity 6 m/s falling to 1.5 m/s at the outlet, the inlet 3 m above tailrace and a loss of 10 % of the inlet velocity head: 1.72 m of velocity head recovered, a pressure head of about 5.8 m absolute and 84 % draft tube efficiency.
Method and article reviewed by FireCAD engineering on 17 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.
Sources
Nag, Power Plant Engineering, 3rd ed. (Tata McGraw-Hill, 2008), ch. 10, sec. 10.8.7 (draft tubes)