Worked example
Example: Furnace off-gas 15 kg/s, 800 to 250 °C, 18 bar(a) saturated, feed 105 °C. The inputs, in the units selected above:
| Input | Value |
|---|---|
| Waste gas flow | 54,000 kg/h |
| Mean specific heat of the gas | 1.1500 kJ/(kg·K) |
| Gas temperature entering | 800.00 °C |
| Gas temperature leaving | 250.00 °C |
| Steam pressure (absolute) | 18.000 bar |
| Steam condition | Dry saturated |
| Superheated steam temperature | 250.00 °C |
| Feedwater temperature | 105.00 °C |
| Casing heat loss, share of the heat given up by the gas | 1.0000 % |
Applying the formula below gives:
| Result | Value |
|---|---|
| Steam generated | 14,361 kg/h |
| Heat to the steam | 9.3926 MW |
| Gas outlet minus saturation temperature | 42.880 K |
Open this example in the calculator and change any input.
Formula
\(\dot Q = \dot m_g\,c_{p,g}\,(T_{g,1} - T_{g,2})\,(1 - \lambda) \qquad \dot m_s = \frac{\dot Q}{h_s - h_{fw}} \qquad \Delta T = T_{g,2} - T_{sat}\)
Variables
| Symbol | Meaning | SI unit |
|---|---|---|
| \(\dot m_g\) | waste gas flow | kg/s |
| \(c_{p,g}\) | gas specific heat | J/(kg·K) |
| \(T_{g,1}\) | gas in | K |
| \(T_{g,2}\) | gas out | K |
| \(p\) | steam pressure | Pa |
| \(\text{state}\) | saturated or superheated | – |
| \(T_s\) | steam temperature | K |
| \(T_{fw}\) | feedwater temperature | K |
| \(\lambda\) | casing loss, share of the heat given up by the gas | – |
| \(\dot m_s\) | steam generated | kg/s |
| \(\dot Q\) | heat to steam | W |
| \(\Delta T\) | gas outlet minus saturation | K |
| \(h_s, h_{fw}\) | steam and feedwater enthalpies (IF97) | J/kg |
| \(T_{sat}\) | saturation temperature | K |
Method and standards
Energy balance of the gas with a mean specific heat; steam enthalpies from FireCAD's IAPWS-IF97.
Where it is used
- Waste heat recovery from furnaces, kilns, incinerators and engines.
- Feasibility of heat recovery projects.
- Checking an existing waste heat boiler.
Common mistakes
- Cooling the gas below saturation in a boiler without an economiser.
- Ignoring dust and fouling.
- Using flue gas specific heat for very different process gas.
Assumptions and limits
- Mean specific heat; steady operation.
- No blowdown: the steam figure is before blowdown. The pinch and the acid dew point are not checked; an outlet below saturation is reported with a warning, not rejected.
- For superheated steam the gas must enter hotter than the steam.
References
- Energy balance
- IAPWS R7-97 IF97
Questions and answers
How much steam can waste gas make?
15 kg/s of furnace off-gas cooled from 800 to 250 °C gives 9.4 MW after 1 % casing loss; making 18 bar(a) saturated steam from 105 °C feedwater that is 4.0 kg/s (14.4 t/h).
How low can the gas go?
Not below the saturation temperature in a boiler alone (here the gas leaves 43 K above it); add an economiser to go lower, keeping above the acid dew point.
What about dusty gas?
Dust lowers heat transfer and erodes tubes; the duty here is the heat available, not how the boiler is laid out.
Method and article reviewed by FireCAD engineering on 11 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.