Waste Heat Boiler Fouling from Operating Data

Clean exit gas temperature of a waste heat boiler at a new gas flow from reference data, against the measured value, and the heat and money lost to fouling.

Thermal power plantProcess steam and utilitiesSugar mill and cogenerationDistillery and ethanolRefinery and petrochemicalChemical and fertiliserIAPWS-IF97 (water and steam)

Inputs

Examples: Ganapathy Q8.17 water tube: 50,000 lb/h at 950 °F, 520 °F measured (book 471 °F, 0.63 MM Btu/h, $15,120)Fire tube, higher flow, exit 7 K above the clean prediction

Results

The measured exit temperature is more than 5 K above the clean prediction: fouling is likely; check gas pressure drop as well.

Present saturation temperature198.30°C
Predicted clean exit gas temperature252.87°C
Exit temperature rise due to fouling7.1271K
Heat lost to fouling98.353kW
Annual cost of the lost heat (currency)12,393

Download PDF CSV Link to this result Compare another case

Log in to save calculations to your dashboard.

Worked example

Example: Ganapathy Q8.17 water tube: 50,000 lb/h at 950 °F, 520 °F measured (book 471 °F, 0.63 MM Btu/h, $15,120). The inputs, in the units selected above:

InputValue
Boiler typeWater tube (U ∝ W_g^0.6)
Reference (clean) gas flow34,019 kg/h
Reference gas inlet temperature537.78 °C
Reference gas exit temperature260.00 °C
Reference steam pressure (absolute)20.684 bar
Present gas flow22,680 kg/h
Present gas inlet temperature510.00 °C
Present steam pressure (absolute)20.684 bar
Measured present exit gas temperature271.11 °C
Gas specific heat1.0886 kJ/(kg·K)
Operating hours per year8,000.0 h
Cost of heat (currency per GJ)2.8435 -

Applying the formula below gives:

ResultValue
Present saturation temperature214.09 °C
Predicted clean exit gas temperature243.85 °C
Exit temperature rise due to fouling27.264 K
Heat lost to fouling186.97 kW
Annual cost of the lost heat (currency)15,311

Open this example in the calculator and change any input.

Formula

\(\ln\frac{T_{g1} - T_s}{T_{g2} - T_s} = \frac{UA}{W_gc_p} \propto W_g^{-0.2}\ \text{(fire tube)},\ W_g^{-0.4}\ \text{(water tube)}, \quad Q_{loss} = W_gc_p(T_{g2,meas} - T_{g2,pred})\)

Variables

Symbol Meaning SI unit
\(\text{type}\) Boiler type -
\(W_{g,1}\) Reference (clean) gas flow kg/s
\(T_{g1,1}\) Reference gas inlet temperature K
\(T_{g2,1}\) Reference gas exit temperature K
\(p_1\) Reference steam pressure (absolute) Pa
\(W_{g,2}\) Present gas flow kg/s
\(T_{g1,2}\) Present gas inlet temperature K
\(p_2\) Present steam pressure (absolute) Pa
\(T_{g2,meas}\) Measured present exit gas temperature K
\(c_p\) Gas specific heat J/(kg·K)
\(t_a\) Operating hours per year s
\(c_E\) Cost of heat (currency per GJ) -
\(T_s\) Present saturation temperature K
\(T_{g2,pred}\) Predicted clean exit gas temperature K
\(\Delta T\) Exit temperature rise due to fouling K
\(Q_{loss}\) Heat lost to fouling W
\(C\) Annual cost of the lost heat (currency) -

Method and standards

Ganapathy's evaporator scaling: the clean exit temperature at the present flow, inlet temperature and pressure follows from the reference test with UA/(W_g c_p) scaled as W_g−0.2 (fire tube) or W_g−0.4 (water tube). The heat lost is the gas heat between the measured and predicted exit temperatures, costed per GJ for the operating hours.

Where it is used

  • Waste heat and fire-tube boiler monitoring.
  • Deciding when to clean.

Common mistakes

  • Using a reference already fouled.
  • Ignoring a change in steam pressure.

Assumptions and limits

  • Evaporator only; gas-side-controlled U.
  • The 5 K margin for flagging fouling is a FireCAD rule of thumb for measurement scatter, not a sourced figure.
  • A measured exit below the clean prediction gives a negative heat loss and dT (no fouling); the cost is then zero.

References

  • Ganapathy
  • Industrial Boilers and Heat Recovery Steam Generators (Marcel Dekker, 2003)
  • Q8.15a and Q8.17 (evaporator performance and fouling inferred from operating data); IAPWS-IF97 saturation

Questions and answers

Why can exit gas temperature reveal fouling?

For an evaporator, ln[(T_in − T_s)/(T_out − T_s)] = UA/(W_g c_p); with U scaling as a power of gas flow, the clean exit temperature at any load follows from one clean test.

What does Ganapathy's example give?

Clean: 75,000 lb/h, 1,000 → 500 °F at 300 psia. At 50,000 lb/h and 950 °F, clean exit should be 471 °F; 520 °F measured means about 0.63 MM Btu/h lost, $15,120 a year at $3/MM Btu.

Why different exponents?

In fire tubes the gas film inside the tubes governs (U ∝ W_g0.8); in water tubes the cross-flow gas film (U ∝ W_g0.6).

Method and article reviewed by FireCAD engineering on 13 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.

Related calculators

Free engineering calculators: every page computes in SI and converts to your units. Results are for engineering estimation; verify critical designs against the referenced standards.

Rejoining the server...

Rejoin failed... trying again in seconds.

Failed to rejoin.
Please retry or reload the page.

The session has been paused by the server.

Failed to resume the session.
Please retry or reload the page.