HRSG Off-Design Performance: Evaporator and Economiser

Steam, gas temperatures and economiser outlet of an unfired HRSG at a new gas flow, temperature and drum pressure, from its design-point data.

Thermal power plantProcess steam and utilitiesSugar mill and cogenerationDistillery and ethanolRefinery and petrochemicalChemical and fertiliserIAPWS-IF97 (water and steam)

Inputs

Examples: Ganapathy Q4.35: 165,000 lb/h at 880 °F, 150 psig (expect 388 °F, 21.7 MM Btu/h, ~25,300 lb/h, ~301 °F)Same HRSG at 120,000 lb/h, 1000 °F, 200 psig

Results

Unfired HRSG with evaporator and economiser; the evaporator NTU scales as W_g^−0.4 and the economiser UA as W_g^m (gas-side controlled), as Ganapathy's Q4.35.

Saturation temperature185.49°C
Gas leaving the evaporator197.56°C
Evaporator duty6,364.3kW
Steam generated11,456kg/h
Water leaving the economiser184.26°C
Economiser duty1,069.1kW
Exit (stack) gas temperature148.52°C

Download PDF CSV Link to this result Compare another case

Log in to save calculations to your dashboard.

Worked example

Example: Ganapathy Q4.35: 165,000 lb/h at 880 °F, 150 psig (expect 388 °F, 21.7 MM Btu/h, ~25,300 lb/h, ~301 °F). The inputs, in the units selected above:

InputValue
Design gas flow17.640 kg/s
Design gas inlet temperature526.67 °C
Design gas temperature leaving the evaporator208.89 °C
Design drum pressure (absolute)14.803 bar
Design economiser duty1,125.4 kW
Design economiser LMTD27.778 K
New gas flow20.790 kg/s
New gas inlet temperature471.11 °C
New drum pressure (absolute)11.356 bar
Feedwater temperature110.00 °C
Blowdown fraction of steam5.0000 %
Gas specific heat, evaporator1.1304 kJ/(kg·K)
Gas specific heat, economiser1.0593 kJ/(kg·K)
Heat retention factor (1 − casing loss)99.000 %
Exponent of gas flow in the economiser UA0.65000 -

Applying the formula below gives:

ResultValue
Saturation temperature185.49 °C
Gas leaving the evaporator197.56 °C
Evaporator duty6,364.5 kW
Steam generated11,456 kg/h
Water leaving the economiser184.26 °C
Economiser duty1,069.1 kW
Exit (stack) gas temperature148.52 °C

Open this example in the calculator and change any input.

Formula

\(\ln\frac{T_{g1} - T_s}{T_{g2} - T_s} = \ln\frac{T_{g1,d} - T_{s,d}}{T_{g2,d} - T_{s,d}}\left(\frac{W_g}{W_{g,d}}\right)^{-0.4}, \quad Q_{ev} = W_gc_ph_l(T_{g1} - T_{g2})\)

\(\dot m_s = \frac{Q_{ev}}{(h_g - h_{w2}) + b(h_f - h_{w2})}, \quad Q_{ec} = \dot m_s(1 + b)(h_{w2} - h_{fw}) = UA\,\Delta T_{lm}, \quad UA = \frac{Q_{e,d}}{\Delta T_{lm,d}}\left(\frac{W_g}{W_{g,d}}\right)^m\)

Variables

Symbol Meaning SI unit
\(W_{g,d}\) Design gas flow kg/s
\(T_{g1,d}\) Design gas inlet temperature K
\(T_{g2,d}\) Design gas temperature leaving the evaporator K
\(p_d\) Design drum pressure (absolute) Pa
\(Q_{e,d}\) Design economiser duty W
\(\Delta T_{lm,d}\) Design economiser LMTD K
\(W_g\) New gas flow kg/s
\(T_{g1}\) New gas inlet temperature K
\(p\) New drum pressure (absolute) Pa
\(T_{fw}\) Feedwater temperature K
\(b\) Blowdown fraction of steam -
\(c_{p,ev}\) Gas specific heat, evaporator J/(kg·K)
\(c_{p,ec}\) Gas specific heat, economiser J/(kg·K)
\(h_l\) Heat retention factor (1 − casing loss) -
\(m\) Exponent of gas flow in the economiser UA -
\(T_s\) Saturation temperature K
\(T_{g2}\) Gas leaving the evaporator K
\(Q_{ev}\) Evaporator duty W
\(\dot m_s\) Steam generated kg/s
\(T_{w2}\) Water leaving the economiser K
\(Q_{ec}\) Economiser duty W
\(T_{g3}\) Exit (stack) gas temperature K

Method and standards

Ganapathy's NTU-type simulation, solved for the economiser outlet temperature by bisection between the feedwater temperature + 0.01 K and the saturation temperature, after checking that the heat balance changes sign in that range. The new gas inlet must be at least 1 K above saturation. If the economiser could heat the water past saturation, the water is taken to leave at saturation, as in Ganapathy's Q4.41, and a warning is shown.

Where it is used

  • Gas turbine HRSG performance at ambient and load changes.
  • Checking guarantees and economiser steaming.

Common mistakes

  • Using design steam per kg of gas at off-design.
  • Ignoring economiser steaming at low pressure.

Assumptions and limits

  • Unfired; no superheater; gas-side-controlled U.
  • The design economiser duty and LMTD are taken as given; they are not checked against the design gas and water temperatures, so enter a consistent design case.
  • A steaming economiser is not modelled: the water is capped at saturation and the economiser duty kept sensible, so the stack temperature is overstated and the steam understated when the warning appears.

References

  • Ganapathy
  • Steam Plant Calculations Manual
  • 2nd ed. (Marcel Dekker, 1993)
  • Q4.35 (off-design simulation of an HRSG) and Q4.34 (design case)
  • Q4.41 (steaming in the economiser); IAPWS-IF97 steam properties

Questions and answers

Why can't I scale steam with gas flow?

The evaporator's exit gas temperature rises and the economiser's pull changes with flow, temperature and pressure; the whole temperature profile shifts.

What does Ganapathy's example give?

Design 140,000 lb/h at 980 °F and 200 psig; at 165,000 lb/h, 880 °F and 150 psig: evaporator gas out 388 °F, 21.7 MM Btu/h, about 25,300 lb/h of steam, water out at saturation and stack about 300 °F.

Why does the economiser steam at off-design?

At lower drum pressure or higher gas flow, the economiser surface can heat water above the new saturation temperature.

Method and article reviewed by FireCAD engineering on 13 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.

Related calculators

Free engineering calculators: every page computes in SI and converts to your units. Results are for engineering estimation; verify critical designs against the referenced standards.

Rejoining the server...

Rejoin failed... trying again in seconds.

Failed to rejoin.
Please retry or reload the page.

The session has been paused by the server.

Failed to resume the session.
Please retry or reload the page.