Worked example
Example: Ganapathy Q8.45b: 68,700 lb/h, 500 psig 690 °F, gas 970 → 380 °F (book ~501,300 lb/h). The inputs, in the units selected above:
| Input | Value |
|---|---|
| Steam flow | 31,162 kg/h |
| Steam pressure (absolute) | 35.487 bar |
| Steam temperature (≤ saturation = dry saturated) | 365.56 °C |
| Feedwater temperature | 110.00 °C |
| Blowdown fraction | 0 % |
| Gas inlet temperature | 521.11 °C |
| Gas exit temperature | 193.33 °C |
| Mean gas specific heat | 1.1304 kJ/(kg·K) |
| Heat retention factor | 99.000 % |
Applying the formula below gives:
| Result | Value |
|---|---|
| Heat to steam and blowdown | 23,175 kW |
| Gas flow | 227,439 kg/h |
| Steam per kg of gas | 0.13701 kg/kg |
Open this example in the calculator and change any input.
Formula
\(W_g = \frac{W_s(h_s - h_{fw}) + bW_s(h_f - h_{fw})}{h_l\bar c_p(T_{g1} - T_{g2})}\)
Variables
| Symbol | Meaning | SI unit |
|---|---|---|
| \(W_s\) | Steam flow | kg/s |
| \(p\) | Steam pressure (absolute) | Pa |
| \(T_s\) | Steam temperature (≤ saturation = dry saturated) | K |
| \(T_{fw}\) | Feedwater temperature | K |
| \(b\) | Blowdown fraction | - |
| \(T_{g1}\) | Gas inlet temperature | K |
| \(T_{g2}\) | Gas exit temperature | K |
| \(\bar c_p\) | Mean gas specific heat | J/(kg·K) |
| \(h_l\) | Heat retention factor | - |
| \(Q_s\) | Heat to steam and blowdown | W |
| \(W_g\) | Gas flow | kg/s |
| \(W_s/W_g\) | Steam per kg of gas | kg/kg |
Method and standards
Energy balance.
Where it is used
- HRSG acceptance tests.
- Gas turbine exhaust flow checks.
Common mistakes
- Mean c_p for the wrong gas analysis.
- Neglecting blowdown and casing loss.
Assumptions and limits
- Steady state; mean c_p over the range.
- Feedwater must be liquid at the steam pressure, and the steam must carry more heat than the feedwater.
References
- Ganapathy
- Industrial Boilers and Heat Recovery Steam Generators (Marcel Dekker, 2003)
- Q8.45a–b (HRSG performance testing; gas flow from an energy balance); IAPWS-IF97
Questions and answers
Why back-calculate gas flow?
Steam flow and temperatures are measured well; exhaust flow in a large duct is not, so the energy balance gives the most reliable gas flow.
What does Ganapathy's example give?
68,700 lb/h of 500 psig, 690 °F steam from 230 °F feedwater with gas cooling from 970 to 380 °F: about 501,000 lb/h of gas.
What next?
Simulate the HRSG at this flow and the actual pressure; compare the predicted steam and exit gas temperature with the measured ones.
Method and article reviewed by FireCAD engineering on 13 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.