Worked example
Example: Ganapathy Q4.38 case: 140,000 lb/h at 980 °F, 25,000 lb/h of 200 psig saturated steam. The inputs, in the units selected above:
| Input | Value |
|---|---|
| Gas flow | 63,503 kg/h |
| Gas inlet temperature (before any burner) | 526.67 °C |
| Reference temperature for gas enthalpy | 15.000 °C |
| Mean gas specific heat from T_ref to T_g | 1.1100 kJ/(kg·K) |
| Duct burner fuel input (LHV) | 0 kW |
| Steam flow | 11,340 kg/h |
| Steam pressure (absolute) | 14.803 bar |
| Steam temperature (0 or ≤ saturation = dry saturated) | -273.15 °C |
| Feedwater temperature | 110.00 °C |
| Blowdown fraction of steam | 2.0000 % |
Applying the formula below gives:
| Result | Value |
|---|---|
| Gas energy above the reference | 10,019 kW |
| Energy to steam and blowdown | 7,357.9 kW |
| HRSG efficiency (PTC 4.4) | 73.443 % |
| Steam temperature used | 197.67 °C |
Open this example in the calculator and change any input.
Formula
\(E = \frac{\dot m_s(h_s - h_{fw}) + b\dot m_s(h_f - h_{fw})}{W_g\bar c_p(T_g - T_{ref}) + Q_{f,LHV}}\)
Variables
| Symbol | Meaning | SI unit |
|---|---|---|
| \(W_g\) | Gas flow | kg/s |
| \(T_g\) | Gas inlet temperature (before any burner) | K |
| \(T_{ref}\) | Reference temperature for gas enthalpy | K |
| \(\bar c_p\) | Mean gas specific heat from T_ref to T_g | J/(kg·K) |
| \(Q_f\) | Duct burner fuel input (LHV) | W |
| \(\dot m_s\) | Steam flow | kg/s |
| \(p\) | Steam pressure (absolute) | Pa |
| \(T_s\) | Steam temperature (0 or ≤ saturation = dry saturated) | K |
| \(T_{fw}\) | Feedwater temperature | K |
| \(b\) | Blowdown fraction of steam | - |
| \(Q_g\) | Gas energy above the reference | W |
| \(Q_s\) | Energy to steam and blowdown | W |
| \(E\) | HRSG efficiency (PTC 4.4) | - |
| \(T_{s,used}\) | Steam temperature used | K |
Method and standards
The efficiency definition of ASME PTC 4.4 (output over gas energy above the reference plus fuel input), with the worked form of Ganapathy Q4.38. PTC 4.4 takes the gas energy from the measured exhaust analysis and its enthalpy; here a mean c_p over T_ref to T_g is used instead, so the result is an estimate on that basis, not a code test result.
Where it is used
- HRSG acceptance and performance monitoring.
- Comparing fired and unfired operation.
Common mistakes
- Mixing HHV and LHV.
- Using a gas enthalpy from another reference temperature.
Assumptions and limits
- Mean c_p; steady state.
- The feedwater must be liquid at the steam pressure (at or below the saturation temperature); the heat to steam must be above zero. An efficiency above 100 % is shown with a warning.
References
- Ganapathy
- Steam Plant Calculations Manual
- 2nd ed. (Marcel Dekker, 1993)
- Q4.38 (HRSG efficiency on the ASME PTC 4.4 basis); IAPWS-IF97 steam properties
Questions and answers
Why is HRSG efficiency low compared with a boiler?
The gas leaves at 150–200 °C above ambient but carries huge excess air; much of its energy is unavoidable stack loss.
Why does firing raise efficiency?
Fuel is burnt in the excess oxygen without adding air, and more steam lowers the stack temperature.
What do the defaults give?
17.6 kg/s (140,000 lb/h) at 980 °F making 25,000 lb/h of 200 psig steam: about 73 %, close to Ganapathy's 71.5 %.
Method and article reviewed by FireCAD engineering on 13 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.