FireCADCalc

HRSG Efficiency on the ASME PTC 4.4 Basis

HRSG efficiency as energy to steam over gas energy above a reference plus duct-burner fuel (LHV), after the ASME PTC 4.4 definition with a mean gas c_p, using IAPWS-IF97.

Thermal power plantProcess steam and utilitiesSugar mill and cogenerationDistillery and ethanolRefinery and petrochemicalChemical and fertiliserASME PTC 4 (fired steam generators)IAPWS-IF97 (water and steam)

Inputs

Examples: Ganapathy Q4.38 case: 140,000 lb/h at 980 °F, 25,000 lb/h of 200 psig saturated steamFired: 10 MW burner, 40 t/h of 40 bar 400 °C

Results

PTC 4.4 bases the gas energy on the measured exhaust analysis and its enthalpy above the code's reference; a mean c_p from the same reference is used here. Firing raises system efficiency because it adds heat without adding air.

Gas energy above the reference36,065kW
Energy to steam and blowdown30,217kW
HRSG efficiency (PTC 4.4)65.596%
Steam temperature used400.00°C

Download PDF CSV Link to this result Compare another case

Log in to save calculations to your dashboard.

Worked example

Example: Ganapathy Q4.38 case: 140,000 lb/h at 980 °F, 25,000 lb/h of 200 psig saturated steam. The inputs, in the units selected above:

InputValue
Gas flow63,503 kg/h
Gas inlet temperature (before any burner)526.67 °C
Reference temperature for gas enthalpy15.000 °C
Mean gas specific heat from T_ref to T_g1.1100 kJ/(kg·K)
Duct burner fuel input (LHV)0 kW
Steam flow11,340 kg/h
Steam pressure (absolute)14.803 bar
Steam temperature (0 or ≤ saturation = dry saturated)-273.15 °C
Feedwater temperature110.00 °C
Blowdown fraction of steam2.0000 %

Applying the formula below gives:

ResultValue
Gas energy above the reference10,019 kW
Energy to steam and blowdown7,357.9 kW
HRSG efficiency (PTC 4.4)73.443 %
Steam temperature used197.67 °C

Open this example in the calculator and change any input.

Formula

\(E = \frac{\dot m_s(h_s - h_{fw}) + b\dot m_s(h_f - h_{fw})}{W_g\bar c_p(T_g - T_{ref}) + Q_{f,LHV}}\)

Variables

Symbol Meaning SI unit
\(W_g\) Gas flow kg/s
\(T_g\) Gas inlet temperature (before any burner) K
\(T_{ref}\) Reference temperature for gas enthalpy K
\(\bar c_p\) Mean gas specific heat from T_ref to T_g J/(kg·K)
\(Q_f\) Duct burner fuel input (LHV) W
\(\dot m_s\) Steam flow kg/s
\(p\) Steam pressure (absolute) Pa
\(T_s\) Steam temperature (0 or ≤ saturation = dry saturated) K
\(T_{fw}\) Feedwater temperature K
\(b\) Blowdown fraction of steam -
\(Q_g\) Gas energy above the reference W
\(Q_s\) Energy to steam and blowdown W
\(E\) HRSG efficiency (PTC 4.4) -
\(T_{s,used}\) Steam temperature used K

Method and standards

The efficiency definition of ASME PTC 4.4 (output over gas energy above the reference plus fuel input), with the worked form of Ganapathy Q4.38. PTC 4.4 takes the gas energy from the measured exhaust analysis and its enthalpy; here a mean c_p over T_ref to T_g is used instead, so the result is an estimate on that basis, not a code test result.

Where it is used

  • HRSG acceptance and performance monitoring.
  • Comparing fired and unfired operation.

Common mistakes

  • Mixing HHV and LHV.
  • Using a gas enthalpy from another reference temperature.

Assumptions and limits

  • Mean c_p; steady state.
  • The feedwater must be liquid at the steam pressure (at or below the saturation temperature); the heat to steam must be above zero. An efficiency above 100 % is shown with a warning.

References

  • Ganapathy
  • Steam Plant Calculations Manual
  • 2nd ed. (Marcel Dekker, 1993)
  • Q4.38 (HRSG efficiency on the ASME PTC 4.4 basis); IAPWS-IF97 steam properties

Questions and answers

Why is HRSG efficiency low compared with a boiler?

The gas leaves at 150–200 °C above ambient but carries huge excess air; much of its energy is unavoidable stack loss.

Why does firing raise efficiency?

Fuel is burnt in the excess oxygen without adding air, and more steam lowers the stack temperature.

What do the defaults give?

17.6 kg/s (140,000 lb/h) at 980 °F making 25,000 lb/h of 200 psig steam: about 73 %, close to Ganapathy's 71.5 %.

Method and article reviewed by FireCAD engineering on 13 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.

Related calculators

Free engineering calculators: every page computes in SI and converts to your units. Results are for engineering estimation; verify critical designs against the referenced standards.

Rejoining the server...

Rejoin failed... trying again in seconds.

Failed to rejoin.
Please retry or reload the page.

The session has been paused by the server.

Failed to resume the session.
Please retry or reload the page.