FireCADCalc

Gas Engine Heat Recovery: Exhaust Steam and Jacket Hot Water

Steam from a gas engine's exhaust (IF97) and hot water from its jacket cooling, with total heat recovered and CHP efficiency from power and fuel input.

Thermal power plantProcess steam and utilitiesSugar mill and cogenerationRefinery and petrochemicalChemical and fertiliserFood, dairy and textileIAPWS-IF97 (water and steam)Boiler

Inputs

Examples: 2 MW gas engine, 430 °C exhaust4.4 MW engine, 10 bar

Results

Jacket heat is at 80–90 °C: use it for hot water, absorption chilling or boiler feed preheating.

The exhaust leaves at 180 °C, less than 10 K above the steam saturation temperature (175 °C): an evaporator alone cannot cool it that far, so this needs an economiser section; for an evaporator-only boiler the steam is overstated.

Fuel input4,761.9kW
Exhaust heat recovered855.56kW
Steam from the exhaust1,285.4kg/h
Total heat recovered1,955.6kW
Overall CHP efficiency83.067%

Download PDF CSV Link to this result Compare another case

Log in to save calculations to your dashboard.

Worked example

Example: 2 MW gas engine, 430 °C exhaust. The inputs, in the units selected above:

InputValue
Engine electrical output2,000.0 kW
Electrical efficiency (on LHV)42.000 %
Exhaust flow11,000 kg/h
Exhaust temperature430.00 °C
Exhaust leaving the boiler180.00 °C
Exhaust specific heat1.1200 kJ/(kg·K)
Jacket and oil cooler heat1,100.0 kW
Steam pressure (absolute)9.0000 bar
Feedwater temperature90.000 °C

Applying the formula below gives:

ResultValue
Fuel input4,761.9 kW
Exhaust heat recovered855.56 kW
Steam from the exhaust1,285.4 kg/h
Total heat recovered1,955.6 kW
Overall CHP efficiency83.067 %

Open this example in the calculator and change any input.

Formula

\(Q_f = \frac{P_e}{\eta_e}, \quad Q_{ex} = \dot m_gc_p(T_g - T_s), \quad \eta_{CHP} = \frac{P_e + Q_{ex} + Q_j}{Q_f}\)

\(\dot m_s = \frac{Q_{ex}}{h_g(p_s) - h_f(T_{fw})}, \quad Q_{th} = Q_{ex} + Q_j\)

Variables

Symbol Meaning SI unit
\(P_e\) Engine electrical output W
\(\eta_e\) Electrical efficiency -
\(\dot m_g\) Exhaust flow kg/s
\(T_g\) Exhaust temperature K
\(T_s\) Exhaust leaving the boiler K
\(c_p\) Exhaust specific heat J/(kg·K)
\(Q_j\) Jacket and oil cooler heat W
\(p_s\) Steam pressure (absolute) Pa
\(T_{fw}\) Feedwater temperature K
\(Q_f\) Fuel input W
\(Q_{ex}\) Exhaust heat recovered W
\(\dot m_s\) Steam from the exhaust kg/s
\(Q_{th}\) Total heat recovered W
\(\eta_{CHP}\) Overall CHP efficiency -
\(h_g\), \(h_f\) saturated steam enthalpy at \(p_s\) and saturated liquid enthalpy at \(T_{fw}\) (IF97) J/kg

Method and standards

Energy balance on the exhaust and the jacket circuit; steam and feedwater enthalpies from FireCAD's IAPWS-IF97.

Where it is used

  • Gas engine CHP studies.

Common mistakes

  • Counting heat that cannot be used.
  • Mixing LHV and HHV efficiencies.

Assumptions and limits

  • LHV basis throughout (electrical efficiency and fuel input).
  • Saturated steam; feedwater enthalpy as saturated liquid at its temperature; no blowdown. Small effects.
  • An evaporator alone can cool the exhaust only to about 10 K above the steam saturation temperature; a lower exit needs an economiser section (a warning appears).
  • A warning appears when power plus recovered heat exceeds the fuel input.

References

  • Energy balances (definitions)
  • Steam and water properties from IAPWS-IF97

Questions and answers

How is engine heat split?

Roughly a third each to power, exhaust and cooling (jacket, oil, intercooler) in large gas engines.

What CHP efficiency is good?

80–90 % using both exhaust and jacket heat.

Why stop the exhaust at 160–180 °C?

Lower temperatures need costly surface and risk condensation.

Method and article reviewed by FireCAD engineering on 13 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.

Related calculators

Free engineering calculators: every page computes in SI and converts to your units. Results are for engineering estimation; verify critical designs against the referenced standards.

Rejoining the server...

Rejoin failed... trying again in seconds.

Failed to rejoin.
Please retry or reload the page.

The session has been paused by the server.

Failed to resume the session.
Please retry or reload the page.