FireCADCalc

Cogeneration vs Power Only: Energy Utilisation

Power and process heat from steam expanded to a back pressure, against power from expansion to a condenser, with IF97 expansions (Ganapathy Q5.02b).

Thermal power plantProcess steam and utilitiesSugar mill and cogenerationRefinery and petrochemicalChemical and fertiliserFood, dairy and textileIAPWS-IF97 (water and steam)Steam turbine

Inputs

Examples: Ganapathy: 50,000 lb/h, 1000 psia 900 °F, 200 psia vs 1 psiaSugar mill 100 t/h, 87 bar 515 °C, 2.5 bar vs 0.1 bar

0 counts all of the exhaust enthalpy as useful, as Ganapathy does.

Results

With condensate enthalpy 0 the process heat counts all the exhaust enthalpy above the IF97 zero (Ganapathy's convention), including heat the condensate takes back; enter the return enthalpy for a realistic figure.

Power, back-pressure scheme18,247kW
Process heat, back-pressure scheme76,988kW
Energy output, back-pressure (power + heat)95,235kW
Power, condensing scheme29,565kW
Energy output ratio3.2212

Download PDF CSV Link to this result Compare another case

Log in to save calculations to your dashboard.

Worked example

Example: Ganapathy: 50,000 lb/h, 1000 psia 900 °F, 200 psia vs 1 psia. The inputs, in the units selected above:

InputValue
Steam flow22.680 t/h
Throttle pressure (absolute)68.948 bar
Throttle temperature482.22 °C
Process (back) pressure (absolute)13.790 bar
Condenser pressure (absolute)6.8948 kPa
Back-pressure expansion efficiency70.000 %
Condensing expansion efficiency75.000 %
Return condensate enthalpy0 kJ/kg

Applying the formula below gives:

ResultValue
Power, back-pressure scheme1,955.7 kW
Process heat, back-pressure scheme19,270 kW
Energy output, back-pressure (power + heat)21,226 kW
Power, condensing scheme6,022.9 kW
Energy output ratio3.5242

Open this example in the calculator and change any input.

Formula

\(P_b = \dot m\eta_b(h_1 - h_{2s,b}), \quad Q_p = \dot m(h_2 - h_r), \quad P_c = \dot m\eta_c(h_1 - h_{2s,c})\)

Variables

Symbol Meaning SI unit
\(\dot m\) Steam flow kg/s
\(p_1\) Throttle pressure (absolute) Pa
\(T_1\) Throttle temperature K
\(p_b\) Process (back) pressure (absolute) Pa
\(p_c\) Condenser pressure (absolute) Pa
\(\eta_b\) Back-pressure expansion efficiency -
\(\eta_c\) Condensing expansion efficiency -
\(h_r\) Return condensate enthalpy J/kg
\(P_b\) Power, back-pressure scheme W
\(Q_p\) Process heat, back-pressure scheme W
\(E_b\) Energy output, back-pressure (power + heat) W
\(P_c\) Power, condensing scheme W
\(E_b/P_c\) Energy output ratio -

Method and standards

Isentropic expansions with IF97 and expansion efficiencies.

Where it is used

  • Cogeneration feasibility.
  • Teaching energy utilisation.

Common mistakes

  • Comparing heat and power as equal value without a price.
  • Ignoring condensate return.

Assumptions and limits

  • No extraction; generator losses not deducted.
  • With \(h_r = 0\) (the default, Ganapathy's convention) the process heat includes the condensate's sensible heat, which inflates \(E_b\) and the ratio; enter the return condensate enthalpy for a realistic comparison.
  • A warning appears when the condensing exhaust is wetter than about 0.88 dryness.
  • The throttle must be superheated (or supercritical) steam; a throttle state below saturation is rejected.

References

  • Ganapathy
  • Steam Plant Calculations Manual
  • 2nd ed. (Marcel Dekker, 1993)
  • Q5.02b (comparison of energy utilisation)
  • Steam and water properties from IAPWS-IF97

Questions and answers

Why does cogeneration use energy better?

The back-pressure exhaust's latent heat goes to process instead of the condenser.

Is power output lower?

Yes: the back-pressure turbine expands over a smaller pressure ratio.

Why is condensate enthalpy an input?

Process heat is the exhaust enthalpy less what returns as condensate; Ganapathy counts it all.

Method and article reviewed by FireCAD engineering on 13 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.

Related calculators

Free engineering calculators: every page computes in SI and converts to your units. Results are for engineering estimation; verify critical designs against the referenced standards.

Rejoining the server...

Rejoin failed... trying again in seconds.

Failed to rejoin.
Please retry or reload the page.

The session has been paused by the server.

Failed to resume the session.
Please retry or reload the page.