FireCADCalc

Polytropic and Isentropic Efficiency of Compressors and Turbines

Converts polytropic (small-stage) efficiency to the overall isentropic efficiency for a compressor or turbine at a pressure ratio, with the temperature ratio.

Thermal power plantProcess steam and utilitiesRefinery and petrochemicalChemical and fertiliser

Inputs

Examples: Compressor ratio 4, 0.88, 288 K

Accepted: 1.01 to 100
Accepted: 50 to 100 %
Accepted: 1.05 to 1.67
Accepted: -123.15 to 1,926.8 °C

Results

For a compressor the isentropic efficiency falls below the polytropic value as the pressure ratio rises (the reheat of each stage raises the work of the next); for a turbine it rises above it.

Polytropic exponent term0.32468
Temperature ratio1.5685
Outlet temperature451.72K
Equivalent isentropic efficiency85.493%

Download PDF CSV Link to this result Compare another case

Log in to save calculations to your dashboard.

Worked example

Example: Compressor ratio 4, 0.88, 288 K. The inputs, in the units selected above:

InputValue
MachineCompressor
Pressure ratio (greater than 1)4.0000 -
Polytropic efficiency88.000 %
Ratio of specific heats1.4000 -
Inlet temperature14.850 °C

Applying the formula below gives:

ResultValue
Polytropic exponent term0.32468
Temperature ratio1.5685
Outlet temperature451.72 K
Equivalent isentropic efficiency85.493 %

Open this example in the calculator and change any input.

Formula

\(\text{compressor: }\frac{n-1}{n} = \frac{1}{\eta_\infty}\frac{\gamma - 1}{\gamma}, \quad \eta_s = \frac{r^{(\gamma-1)/\gamma} - 1}{r^{(n-1)/n} - 1}\)

\(\text{turbine: }\frac{n-1}{n} = \eta_\infty\frac{\gamma - 1}{\gamma}, \quad \eta_s = \frac{1 - r^{-(n-1)/n}}{1 - r^{-(\gamma-1)/\gamma}}\)

Variables

Symbol Meaning SI unit
\(\text{machine}\) Machine -
\(r\) Pressure ratio (greater than 1) -
\(\eta_\infty\) Polytropic efficiency -
\(\gamma\) Ratio of specific heats -
\(T_1\) Inlet temperature K
\((n-1)/n\) Polytropic exponent term -
\(T_2/T_1\) Temperature ratio -
\(T_2\) Outlet temperature K
\(\eta_s\) Equivalent isentropic efficiency -

Method and standards

Polytropic (small-stage) efficiency relations.

Where it is used

  • Comparing compressors of different pressure ratio.
  • Cycle calculations at high pressure ratio.

Common mistakes

  • Using the compressor formula for a turbine.
  • Mixing total and static conditions.

Assumptions and limits

  • Ideal gas with constant γ.

Questions and answers

Why use polytropic efficiency?

It describes the aerodynamic quality of the blading independent of pressure ratio, so machines of different pressure ratio can be compared fairly.

What do the defaults represent?

A compressor at pressure ratio 30 with 0.89 polytropic efficiency from 288 K: (n − 1)/n = 0.3210, 858 K and an equivalent isentropic efficiency of 83.0 %.

Method and article reviewed by FireCAD engineering on 17 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.

Sources

Saravanamuttoo, Rogers and Cohen, Gas Turbine Theory, 4th ed. (Longman, 1996), sec. 2.2, eqs. 2.19-2.20 and Example 2.3

Related calculators

Free engineering calculators: every page computes in SI and converts to your units. Results are for engineering estimation; verify critical designs against the referenced standards.

Rejoining the server...

Rejoin failed... trying again in seconds.

Failed to rejoin.
Please retry or reload the page.

The session has been paused by the server.

Failed to resume the session.
Please retry or reload the page.