Worked example
Example: rp 15, 1 200 °C, 86 % / 89 %, 100 kg/s. The inputs, in the units selected above:
| Input | Value |
|---|---|
| Compressor inlet temperature | 15.000 °C |
| Pressure ratio | 15.000 - |
| Turbine inlet temperature | 1,200.0 °C |
| Compressor isentropic efficiency | 86.000 % |
| Turbine isentropic efficiency | 89.000 % |
| Specific heat of the air and gas | 1.0050 kJ/(kg·K) |
| Ratio of specific heats | 1.4000 - |
| Air mass flow | 360,000 kg/h |
Applying the formula below gives:
| Result | Value |
|---|---|
| Compressor outlet temperature | 406.29 °C |
| Turbine outlet (exhaust) temperature | 493.70 °C |
| Compressor work | 393.25 kJ/kg |
| Turbine work | 709.84 kJ/kg |
| Net work | 316.59 kJ/kg |
| Heat added | 797.68 kJ/kg |
| Thermal efficiency | 39.689 % |
| Ideal (isentropic) cycle efficiency | 53.871 % |
| Back-work ratio w_c / w_t | 55.400 % |
| Net power | 31.659 MW |
Open this example in the calculator and change any input.
Formula
\(T_2 = T_1 + \frac{T_1 (r_p^{(\gamma-1)/\gamma} - 1)}{\eta_c}, \quad T_4 = T_3 - \eta_t\, T_3 \left(1 - r_p^{-(\gamma-1)/\gamma}\right)\)
\(w_c = c_p (T_2 - T_1), \quad w_t = c_p (T_3 - T_4), \quad \eta = \frac{w_t - w_c}{c_p (T_3 - T_2)}\)
\(\eta_{ideal} = 1 - r_p^{-(\gamma-1)/\gamma}\)
Variables
| Symbol | Meaning | SI unit |
|---|---|---|
| \(T_1\) | Compressor inlet temperature | K |
| \(r_p\) | Pressure ratio | - |
| \(T_3\) | Turbine inlet temperature | K |
| \(\eta_c\) | Compressor isentropic efficiency | - |
| \(\eta_t\) | Turbine isentropic efficiency | - |
| \(c_p\) | Specific heat of the air and gas | J/(kg·K) |
| \(\gamma\) | Ratio of specific heats | - |
| \(\dot m\) | Air mass flow | kg/s |
| \(T_2\) | Compressor outlet temperature | K |
| \(T_4\) | Turbine outlet (exhaust) temperature | K |
| \(w_c\) | Compressor work | J/kg |
| \(w_t\) | Turbine work | J/kg |
| \(w_{net}\) | Net work | J/kg |
| \(q_{in}\) | Heat added | J/kg |
| \(\eta\) | Thermal efficiency | - |
| \(\eta_{ideal}\) | Ideal (isentropic) cycle efficiency | - |
| \(BWR\) | Back-work ratio w_c / w_t | - |
| \(P\) | Net power | W |
Method and standards
The air-standard Brayton cycle with constant specific heats: isentropic compression and expansion corrected by the component isentropic efficiencies, heat added at constant pressure.
Where it is used
- Teaching and first estimates of gas turbine performance.
- Seeing how pressure ratio and firing temperature trade off.
- Estimating exhaust temperature for heat recovery.
Common mistakes
- Applying the ideal efficiency to a real machine.
- Using one cp for air and hot gas when accuracy matters (use the gas properties calculator).
- Mixing pressure ratio with pressure difference.
Assumptions and limits
- Air-standard: no fuel mass, no pressure losses, constant cp and γ.
- No cooling air or blade cooling losses.
- One c_p and γ for air and hot gas: at 1 200 °C the gas has c_p about 1.15–1.2 kJ/(kg·K) and γ about 1.33, so a real machine differs materially. A note appears if c_p and γ imply a gas constant far from air.
Questions and answers
What efficiency does a pressure ratio of 15 give?
With 1 200 °C at the turbine inlet and 86 % / 89 % component efficiencies, 39.7 %; the ideal cycle at the same ratio gives 53.9 %.
Why is the exhaust so hot?
Expansion ends at about atmospheric pressure, so the exhaust leaves at 400–600 °C, which a heat recovery boiler can use.
Method and article reviewed by FireCAD engineering on 12 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.
Sources
Air-standard Brayton cycle (Çengel and Boles, Thermodynamics: An Engineering Approach, ch. 9)