FireCADCalc

Morse Test: Indicated Power of a Multi-Cylinder Engine

Indicated power of each cylinder and of a multi-cylinder engine from the brake power with all cylinders firing and with each cylinder cut out in turn (Morse test).

Boiler operation engineer (BOE) examinations

Inputs

Examples: Four cylindersSix cylinders

Results

Keep the speed constant during each cut-out by reducing the brake load; friction is assumed unchanged.

Indicated power is the sum over the cylinders tested: enter a reading for every cylinder of the engine (up to six), or IP is understated.

Indicated power (sum over tested cylinders)102.60kW
Friction power IP − BP6.6000kW
Mechanical efficiency93.567%
Cylinders tested6.0000

Download PDF CSV Link to this result Compare another case

Log in to save calculations to your dashboard.

Worked example

Example: Four cylinders. The inputs, in the units selected above:

InputValue
Brake power, all cylinders firing32.000 kW
Brake power with cylinder 1 cut out (0 if not tested)22.500 kW
Brake power with cylinder 2 cut out (0 if not tested)22.200 kW
Brake power with cylinder 3 cut out (0 if not tested)22.800 kW
Brake power with cylinder 4 cut out (0 if not tested)22.400 kW
Brake power with cylinder 5 cut out (0 if not tested)0 kW
Brake power with cylinder 6 cut out (0 if not tested)0 kW

Applying the formula below gives:

ResultValue
Indicated power (sum over tested cylinders)38.100 kW
Friction power IP − BP6.1000 kW
Mechanical efficiency83.990 %
Cylinders tested4.0000

Open this example in the calculator and change any input.

Formula

\(IP_i = BP - BP_{-i}, \quad IP = \sum IP_i, \quad \eta_m = \frac{BP}{IP}\)

Variables

Symbol Meaning SI unit
\(BP\) Brake power, all cylinders firing W
\(BP_{1}\) Brake power with cylinder 1 cut out (0 if not tested) W
\(BP_{2}\) Brake power with cylinder 2 cut out (0 if not tested) W
\(BP_{3}\) Brake power with cylinder 3 cut out (0 if not tested) W
\(BP_{4}\) Brake power with cylinder 4 cut out (0 if not tested) W
\(BP_{5}\) Brake power with cylinder 5 cut out (0 if not tested) W
\(BP_{6}\) Brake power with cylinder 6 cut out (0 if not tested) W
\(IP\) Indicated power (sum over tested cylinders) W
\(FP\) Friction power IP − BP W
\(\eta_m\) Mechanical efficiency -
\(z\) Cylinders tested -

Method and standards

Morse test.

Where it is used

  • Engine laboratories.
  • Examinations.

Common mistakes

  • Changing speed between readings.
  • Leaving untested cylinders out of the count.

Assumptions and limits

  • Friction unchanged with a cylinder cut out.
  • Up to six cylinders. The engine's cylinder count is not an input, so the calculator cannot check that every cylinder was cut out; a missing cylinder understates IP.

References

  • Morse test: IP_i = BP − BP_i with cylinder i cut out at constant speed; IP = Σ IP_i

Questions and answers

32 kW firing; 22.5, 22.2, 22.8 and 22.4 kW with each cut out?

IP 38.1 kW: mechanical efficiency 84.0 %.

Why keep speed constant?

So friction stays the same in each reading.

Single cylinder?

Not possible: use Willans line or motoring.

Method and article reviewed by FireCAD engineering on 12 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.

Related calculators

Free engineering calculators: every page computes in SI and converts to your units. Results are for engineering estimation; verify critical designs against the referenced standards.

Rejoining the server...

Rejoin failed... trying again in seconds.

Failed to rejoin.
Please retry or reload the page.

The session has been paused by the server.

Failed to resume the session.
Please retry or reload the page.