Worked example
Example: 1.039 L, 69.3 mL. The inputs, in the units selected above:
| Input | Value |
|---|---|
| Swept volume per cylinder | 1.0390 L |
| Clearance volume | 0.069300 L |
| Target compression ratio | 17.000 - |
Applying the formula below gives:
| Result | Value |
|---|---|
| Compression ratio (V_s + V_c)/V_c | 15.993 |
| Clearance for the target | 0.064937 L |
Open this example in the calculator and change any input.
Formula
\(r = \frac{V_s + V_c}{V_c}, \quad V_c = \frac{V_s}{r - 1}\)
Variables
| Symbol | Meaning | SI unit |
|---|---|---|
| \(V_s\) | Swept volume per cylinder | m³ |
| \(V_c\) | Clearance volume | m³ |
| \(r_t\) | Target compression ratio | - |
| \(r\) | Compression ratio (V_s + V_c)/V_c | - |
| \(V_{c,t}\) | Clearance for the target | m³ |
Method and standards
Geometry.
Where it is used
- Engine overhaul checks.
- Examinations.
Common mistakes
- Total displacement with per-cylinder clearance.
- mL vs L.
Assumptions and limits
- One cylinder.
- Static (geometric) ratio. The effective ratio is lower when the inlet valve closes late (Miller and Atkinson timing), and is not computed.
References
- r = (V_s + V_c)/V_c
Questions and answers
1.039 L swept with 69.3 mL clearance?
r = 16.0.
Clearance for 17:1?
64.9 mL.
Higher ratio?
Better efficiency, but more pressure and, in petrol engines, knock.
Method and article reviewed by FireCAD engineering on 12 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.