Worked example
Example: Four cylinders. The inputs, in the units selected above:
| Input | Value |
|---|---|
| Brake power, all cylinders firing | 32.000 kW |
| Brake power with cylinder 1 cut out (0 if not tested) | 22.500 kW |
| Brake power with cylinder 2 cut out (0 if not tested) | 22.200 kW |
| Brake power with cylinder 3 cut out (0 if not tested) | 22.800 kW |
| Brake power with cylinder 4 cut out (0 if not tested) | 22.400 kW |
| Brake power with cylinder 5 cut out (0 if not tested) | 0 kW |
| Brake power with cylinder 6 cut out (0 if not tested) | 0 kW |
Applying the formula below gives:
| Result | Value |
|---|---|
| Indicated power (sum over tested cylinders) | 38.100 kW |
| Friction power IP − BP | 6.1000 kW |
| Mechanical efficiency | 83.990 % |
| Cylinders tested | 4.0000 |
Open this example in the calculator and change any input.
Formula
\(IP_i = BP - BP_{-i}, \quad IP = \sum IP_i, \quad \eta_m = \frac{BP}{IP}\)
Variables
| Symbol | Meaning | SI unit |
|---|---|---|
| \(BP\) | Brake power, all cylinders firing | W |
| \(BP_{1}\) | Brake power with cylinder 1 cut out (0 if not tested) | W |
| \(BP_{2}\) | Brake power with cylinder 2 cut out (0 if not tested) | W |
| \(BP_{3}\) | Brake power with cylinder 3 cut out (0 if not tested) | W |
| \(BP_{4}\) | Brake power with cylinder 4 cut out (0 if not tested) | W |
| \(BP_{5}\) | Brake power with cylinder 5 cut out (0 if not tested) | W |
| \(BP_{6}\) | Brake power with cylinder 6 cut out (0 if not tested) | W |
| \(IP\) | Indicated power (sum over tested cylinders) | W |
| \(FP\) | Friction power IP − BP | W |
| \(\eta_m\) | Mechanical efficiency | - |
| \(z\) | Cylinders tested | - |
Method and standards
Morse test.
Where it is used
- Engine laboratories.
- Examinations.
Common mistakes
- Changing speed between readings.
- Leaving untested cylinders out of the count.
Assumptions and limits
- Friction unchanged with a cylinder cut out.
- Up to six cylinders. The engine's cylinder count is not an input, so the calculator cannot check that every cylinder was cut out; a missing cylinder understates IP.
References
- Morse test: IP_i = BP − BP_i with cylinder i cut out at constant speed; IP = Σ IP_i
Questions and answers
32 kW firing; 22.5, 22.2, 22.8 and 22.4 kW with each cut out?
IP 38.1 kW: mechanical efficiency 84.0 %.
Why keep speed constant?
So friction stays the same in each reading.
Single cylinder?
Not possible: use Willans line or motoring.
Method and article reviewed by FireCAD engineering on 12 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.