Worked example
Example: 100 TCH quadruple. The inputs, in the units selected above:
| Input | Value |
|---|---|
| Crushing rate | 100.00 t/h |
| Evaporator evaporation per tonne cane | 800.00 kg/t |
| Of which leaves as vapour to the condenser | 150.00 kg/t |
| Pan evaporation per tonne cane | 120.00 kg/t |
| Pan vapour to the condensers | 120.00 kg/t |
| Imbibition per tonne cane | 300.00 kg/t |
| Boiler make-up from vapour condensate | 50.000 kg/t |
| Other process uses | 100.00 kg/t |
Applying the formula below gives:
| Result | Value |
|---|---|
| Vapour condensate made per tonne cane | 650.00 kg/t |
| Used per tonne cane | 450.00 kg/t |
| Surplus per tonne cane | 200.00 kg/t |
| Surplus | 20.000 t/h |
Open this example in the calculator and change any input.
Formula
\(C = E - e_x + E_p - p_x, \quad U = w + m_u + o, \quad \dot m_s = (C - U)A\)
Variables
| Symbol | Meaning | SI unit |
|---|---|---|
| \(A\) | Crushing rate | kg/s |
| \(E\) | Evaporator evaporation per tonne cane | kg/kg |
| \(e_x\) | Of which leaves as vapour to the condenser | kg/kg |
| \(E_p\) | Pan evaporation per tonne cane | kg/kg |
| \(p_x\) | Pan vapour to the condensers | kg/kg |
| \(w\) | Imbibition per tonne cane | kg/kg |
| \(m_u\) | Boiler make-up from vapour condensate | kg/kg |
| \(o\) | Other process uses | kg/kg |
| \(C\) | Vapour condensate made per tonne cane | kg/kg |
| \(U\) | Used per tonne cane | kg/kg |
| \(C - U\) | Surplus per tonne cane | kg/kg |
| \(\dot m_s\) | Surplus | kg/s |
Method and standards
Water balance.
Where it is used
- Zero liquid discharge planning.
- Reducing fresh water intake.
Common mistakes
- Counting exhaust condensate.
- Ignoring condensate used for wash water.
Assumptions and limits
- Steady crush.
- A negative surplus is a deficit to be made up with other water; it is flagged.
References
- Mass balance of vapour condensates in a sugar factory
Questions and answers
Where does the condensate come from?
Water evaporated from juice: about 0.8 t per tonne cane in the evaporator and more in the pans.
Why is there a surplus?
Cane is about 70 % water; once imbibition and make-up are covered the rest must be reused or treated.
Why exclude vapour to the condensers?
It condenses into the cooling water and leaves with it.
Method and article reviewed by FireCAD engineering on 13 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.