FireCADCalc

Vapour Condensate Surplus and Effluent per Tonne Cane

Condensate made from juice vapours (evaporator and pans) per tonne cane, its uses (imbibition, boiler make-up, process), and the surplus to treat or recycle.

Sugar mill and cogenerationDistillery and ethanol

Inputs

Examples: 100 TCH quadrupleHeavy bleeding

Results

Vapour condensed in calandrias and heaters is the factory's main water source; vapour to the condensers mixes with cooling water and is lost to it. Exhaust condensate returns to the boilers and is not counted here.

Vapour condensate made per tonne cane650.00kg/t
Used per tonne cane450.00kg/t
Surplus per tonne cane200.00kg/t
Surplus20.000t/h

Download PDF CSV Link to this result Compare another case

Log in to save calculations to your dashboard.

Worked example

Example: 100 TCH quadruple. The inputs, in the units selected above:

InputValue
Crushing rate100.00 t/h
Evaporator evaporation per tonne cane800.00 kg/t
Of which leaves as vapour to the condenser150.00 kg/t
Pan evaporation per tonne cane120.00 kg/t
Pan vapour to the condensers120.00 kg/t
Imbibition per tonne cane300.00 kg/t
Boiler make-up from vapour condensate50.000 kg/t
Other process uses100.00 kg/t

Applying the formula below gives:

ResultValue
Vapour condensate made per tonne cane650.00 kg/t
Used per tonne cane450.00 kg/t
Surplus per tonne cane200.00 kg/t
Surplus20.000 t/h

Open this example in the calculator and change any input.

Formula

\(C = E - e_x + E_p - p_x, \quad U = w + m_u + o, \quad \dot m_s = (C - U)A\)

Variables

Symbol Meaning SI unit
\(A\) Crushing rate kg/s
\(E\) Evaporator evaporation per tonne cane kg/kg
\(e_x\) Of which leaves as vapour to the condenser kg/kg
\(E_p\) Pan evaporation per tonne cane kg/kg
\(p_x\) Pan vapour to the condensers kg/kg
\(w\) Imbibition per tonne cane kg/kg
\(m_u\) Boiler make-up from vapour condensate kg/kg
\(o\) Other process uses kg/kg
\(C\) Vapour condensate made per tonne cane kg/kg
\(U\) Used per tonne cane kg/kg
\(C - U\) Surplus per tonne cane kg/kg
\(\dot m_s\) Surplus kg/s

Method and standards

Water balance.

Where it is used

  • Zero liquid discharge planning.
  • Reducing fresh water intake.

Common mistakes

  • Counting exhaust condensate.
  • Ignoring condensate used for wash water.

Assumptions and limits

  • Steady crush.
  • A negative surplus is a deficit to be made up with other water; it is flagged.

References

  • Mass balance of vapour condensates in a sugar factory

Questions and answers

Where does the condensate come from?

Water evaporated from juice: about 0.8 t per tonne cane in the evaporator and more in the pans.

Why is there a surplus?

Cane is about 70 % water; once imbibition and make-up are covered the rest must be reused or treated.

Why exclude vapour to the condensers?

It condenses into the cooling water and leaves with it.

Method and article reviewed by FireCAD engineering on 13 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.

Related calculators

Free engineering calculators: every page computes in SI and converts to your units. Results are for engineering estimation; verify critical designs against the referenced standards.

Rejoining the server...

Rejoin failed... trying again in seconds.

Failed to rejoin.
Please retry or reload the page.

The session has been paused by the server.

Failed to resume the session.
Please retry or reload the page.