Vacuum Leak Test: Air Entering a Vessel

Air leaking into an evaporator or pan from the fall in vacuum over a time, its volume and temperatures (Hugot's leak test, p. 880).

Sugar mill and cogeneration

Inputs

Examples: Hugot example: 50 m3, 60 -> 50 cm in 36 minWet vessel

Results

Hugot's example: 50 m³ falling from 60 to 50 cm vacuum in 36 min (20 → 25 °C) admits about 12.7 kg of air per hour. Test with the vessel closed and empty; start above 36 cm vacuum so the flow through leaks stays critical.

Air at the start12.703kg
Air at the end20.282kg
Air leakage12.632kg/h

Download PDF CSV Link to this result Compare another case

Log in to save calculations to your dashboard.

Worked example

Example: Hugot example: 50 m3, 60 -> 50 cm in 36 min. The inputs, in the units selected above:

InputValue
Vessel volume50.000 m³
Absolute pressure at the start21.378 kPa
Absolute pressure at the end34.716 kPa
Temperature at the start20.000 °C
Temperature at the end25.000 °C
Duration36.000 min
Water vapour in the vesselDry vessel (Hugot's test)

Applying the formula below gives:

ResultValue
Air at the start12.703 kg
Air at the end20.282 kg
Air leakage12.632 kg/h

Open this example in the calculator and change any input.

Formula

\(m_i = \frac{p_{a,i}V}{R_a T_i}, \quad \dot m_L = \frac{m_2 - m_1}{t}\)

Variables

Symbol Meaning SI unit
\(V\) Vessel volume m³
\(p_1\) Absolute pressure at the start Pa
\(p_2\) Absolute pressure at the end Pa
\(T_1\) Temperature at the start K
\(T_2\) Temperature at the end K
\(t\) Duration s
\(\text{vapour}\) Water vapour in the vessel -
\(m_1\) Air at the start kg
\(m_2\) Air at the end kg
\(\dot m_L\) Air leakage kg/s

Method and standards

Ideal-gas balance of the air in the vessel.

Where it is used

  • Commissioning evaporators and pans.
  • Finding air leaks.

Common mistakes

  • Using vacuum readings as absolute pressure.
  • A test that starts too close to atmospheric pressure.

Assumptions and limits

  • Uniform temperature in the vessel.
  • The leak flow is critical only while the vessel is below about 0.53 atm absolute (above about 36 cm vacuum); a test that ends above it is flagged, because the average rate is then understated.

References

  • Hugot
  • Handbook of Cane Sugar Engineering
  • 3rd ed. (Elsevier, 1986)
  • ch. 40
  • leak test (eqn 40.16 and example)
  • pp. 879–880
  • Ideal-gas law for air

Questions and answers

Why start above 36 cm vacuum?

Below about 0.53 of atmospheric pressure the flow through a leak is critical and independent of the vessel pressure, so the rate stays constant during the test.

Dry or wet vessel?

Hugot's test takes the vessel dry; if water is present its vapour pressure must be subtracted.

What is acceptable?

Compare with the air pump capacity: leaks should be a small part of it.

Method and article reviewed by FireCAD engineering on 13 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.

Related calculators

Free engineering calculators: every page computes in SI and converts to your units. Results are for engineering estimation; verify critical designs against the referenced standards.

Rejoining the server...

Rejoin failed... trying again in seconds.

Failed to rejoin.
Please retry or reload the page.

The session has been paused by the server.

Failed to resume the session.
Please retry or reload the page.