Condenser Injection and Tail Water Pumps

Injection water and tail (warm) water flows of a barometric condenser (Hugot eqns 40.24–40.25) and the pump power for their heads (40.26), with margin.

Sugar mill and cogenerationPump

Inputs

Examples: Hugot heads 11 and 15.5 mStart-up head

Hugot's example: 11 m in service, 17 m at start-up.

Results

The injection pump runs against the vacuum once the condenser works; size it for the start-up head, when there is no vacuum.

Injection water920.00m³/h
Warm (tail) water943.00m³/h
Injection pump power54.621kW
Warm water pump power51.047kW

Download PDF CSV Link to this result Compare another case

Log in to save calculations to your dashboard.

Worked example

Example: Hugot heads 11 and 15.5 m. The inputs, in the units selected above:

InputValue
Vapour condensed11,000 kg/h
Water per kg vapour50.000 -
Injection pump head11.000 m
Warm water pump head15.500 m
Pump efficiency75.000 %
Flow margin1.2000 -

Applying the formula below gives:

ResultValue
Injection water660.00 m³/h
Warm (tail) water673.20 m³/h
Injection pump power26.369 kW
Warm water pump power37.899 kW

Open this example in the calculator and change any input.

Formula

\(Q_1 = kQW, \quad Q_2 = kQ(W + 1), \quad P = \frac{\rho g Q H}{\eta}\)

Variables

Symbol Meaning SI unit
\(Q\) Vapour condensed kg/s
\(W\) Water per kg vapour -
\(H_1\) Injection pump head m
\(H_2\) Warm water pump head m
\(\eta\) Pump efficiency -
\(k\) Flow margin -
\(Q_1\) Injection water m³/s
\(Q_2\) Warm (tail) water m³/s
\(P_1\) Injection pump power W
\(P_2\) Warm water pump power W

Method and standards

Hugot's pump balance.

Where it is used

  • Condenser pump sizing.
  • Energy audits.

Common mistakes

  • Using vapour flow as water flow.
  • Ignoring start-up head.

Assumptions and limits

  • Water at about 1000 kg/m³.
  • The margin k is applied to the flows, and so also to the power; the power is then a pump-sizing figure, not the running power. For running power set k = 1.

References

  • Hugot
  • Handbook of Cane Sugar Engineering
  • 3rd ed. (Elsevier, 1986)
  • ch. 40
  • pumps for condensers
  • eqns 40.24–40.26 and examples
  • pp. 883–884

Questions and answers

Why does the warm pump carry more?

It takes the condensed vapour as well as the injection water.

Why size for start-up?

Before vacuum forms the injection pump must lift water all the way into the condenser.

Water density?

Taken as 1000 kg/m³ for the power.

Method and article reviewed by FireCAD engineering on 13 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.

Related calculators

Free engineering calculators: every page computes in SI and converts to your units. Results are for engineering estimation; verify critical designs against the referenced standards.

Rejoining the server...

Rejoin failed... trying again in seconds.

Failed to rejoin.
Please retry or reload the page.

The session has been paused by the server.

Failed to resume the session.
Please retry or reload the page.