FireCADCalc

Pure Ethanol at 20 °C in a Steel Tank Measured at t

Volume of pure ethanol at 20 °C and bulk volume at 20 °C of spirit measured at temperature t in a steel container calibrated at 20 °C, OIML R 22 Tables XI.

Distillery and ethanolTank and drum

Inputs

Examples: 10 000 L of 96 % vol at 30 °C5 000 L of 40 % mass at 5 °C

R 22 formula range −20 to +40 °C.
R 22: 36 × 10⁻⁶ /°C, the volume coefficient (three times the linear 12 × 10⁻⁶). Shown in µm/(m·K), i.e. 10⁻⁶ /K.

Results

Density at t945.89kg/m³
Bulk volume at 20 °C5,054.7L
Pure ethanol at 20 °C2,395.7L
Pure ethanol per unit measured volume47.913%

Download PDF CSV Link to this result Compare another case

Log in to save calculations to your dashboard.

Worked example

Example: 10 000 L of 96 % vol at 30 °C. The inputs, in the units selected above:

InputValue
Volume measured at t10,000 L
Strength entered as% vol (by volume at 20 °C)
Alcoholic strength96.000 %
Temperature of the liquid30.000 °C
Cubical (volume) expansion of the steel, about 3 × linear36.000 µm/(m·K)

Applying the formula below gives:

ResultValue
Density at t798.72 kg/m³
Bulk volume at 20 °C9,895.8 L
Pure ethanol at 20 °C9,500.0 L
Pure ethanol per unit measured volume95.000 %

Open this example in the calculator and change any input.

Formula

\(v = V_t\,\frac{p\,\rho_t}{\rho_{20}(1)}[1 + \beta(t - 20)] = V_t\,\frac{q\,\rho_t}{\rho_{20}}[1 + \beta(t - 20)], \quad V_{20} = V_t\,\frac{\rho_t}{\rho_{20}}[1 + \beta(t - 20)]\)

Variables

Symbol Meaning SI unit
\(V_t\) Volume measured at t m³
\(\text{basis}\) Strength entered as -
\(s\) Alcoholic strength -
\(t\) Temperature of the liquid K
\(\beta\) Cubical (volume) expansion of the steel, about 3 × linear 1/K
\(\rho_t\) Density at t kg/m³
\(V_{20}\) Bulk volume at 20 °C m³
\(v\) Pure ethanol at 20 °C m³
\(v/V_t\) Pure ethanol per unit measured volume -

Method and standards

R 22 Annex I formulas for Tables XI.

Where it is used

  • Excise stock-taking.
  • Tanker and receiver gauging.

Common mistakes

  • Multiplying volume at t by % vol directly.
  • Forgetting the tank's own expansion.

Assumptions and limits

  • Tank calibrated at 20 °C.
  • β is the cubical (volume) coefficient, 36 × 10⁻⁶ /K in R 22; entering the linear coefficient (about 12 × 10⁻⁶) would under-correct the tank by two thirds.
  • Uniform temperature.

References

  • OIML R 22 (1973)
  • Alcoholometry
  • and International Alcoholometric Tables (1975)
  • Annex I
  • Tables XIa and XIb

Questions and answers

Why both a density and a steel term?

The liquid shrinks or swells with temperature, and the tank's calibrated volume grows by β(t − 20).

What is the R 22 formula?

v = p ρt/ρ20(100 %) × [1 + β(t − 20)] per unit measured volume, the same as q ρt/ρ20 × [1 + β(t − 20)].

Is this the same as bulk-litres × % vol?

Only at 20 °C.

Method and article reviewed by FireCAD engineering on 13 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.

Related calculators

Free engineering calculators: every page computes in SI and converts to your units. Results are for engineering estimation; verify critical designs against the referenced standards.

Rejoining the server...

Rejoin failed... trying again in seconds.

Failed to rejoin.
Please retry or reload the page.

The session has been paused by the server.

Failed to resume the session.
Please retry or reload the page.