Worked example
Example: 948.2 kg/m3 at 20 °C. The inputs, in the units selected above:
| Input | Value |
|---|---|
| Measured density at t | 948.20 kg/m³ |
| Temperature of the liquid | 20.000 °C |
Applying the formula below gives:
| Result | Value |
|---|---|
| Strength by mass | 33.214 % |
| Strength by volume at 20 °C | 39.903 % |
| Density at 20 °C | 948.20 kg/m³ |
Open this example in the calculator and change any input.
Formula
\(\rho(p, t) = \rho_{\text{measured}} \Rightarrow p, \quad q = p\,\frac{\rho_{20}(p)}{\rho_{20}(1)}, \quad \rho_{20}(1) \approx 789.24\ \mathrm{kg/m^3}\)
Variables
| Symbol | Meaning | SI unit |
|---|---|---|
| \(\rho_t\) | Measured density at t | kg/m³ |
| \(t\) | Temperature of the liquid | K |
| \(p\) | Strength by mass | - |
| \(q\) | Strength by volume at 20 °C | - |
| \(\rho_{20}\) | Density at 20 °C | kg/m³ |
Method and standards
Inversion of the R 22 formula by bisection, as Tables V–VII are built.
Where it is used
- Laboratory strength by density meter.
- Checking spirit receivers.
Common mistakes
- Measuring a sugared or coloured product without distilling.
- Mixing up density and specific gravity.
Assumptions and limits
- Binary ethanol–water.
- Density between pure ethanol and water at t.
- Below 0 °C dilute mixtures freeze; the R 22 formula is then applied to supercooled liquid and the result has no practical meaning for a frozen sample.
- The inversion assumes density falls steadily with strength at a fixed temperature, as the R 22 formula does over its range.
References
- OIML R 22 (1973)
- Alcoholometry
- and International Alcoholometric Tables (1975): formula of Wagenbreth and Blanke
- pp. 12–13
Questions and answers
How is the strength found?
The R 22 formula is solved for the strength by mass that gives the measured density at the measured temperature.
Does a digital density meter need a glass correction?
No, an oscillating-tube meter reports true density; glass instruments need the corrections in the hydrometer calculators.
What if the sample holds sugar or extract?
The result is wrong: distil the sample first.
Method and article reviewed by FireCAD engineering on 13 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.