FireCADCalc

Steam Pipe Pressure Drop

Pressure drop of a steam line by Darcy–Weisbach and Colebrook, with steam density and viscosity from IAPWS-IF97, fittings by K, velocity and Reynolds number.

Thermal power plantProcess steam and utilitiesRefinery and petrochemicalChemical and fertiliserIAPWS-IF97 (water and steam)Boiler

Inputs

Examples: 10 t/h saturated at 10.5 bar(a), DN150 (154.1 mm), 100 m, K 550 t/h at 66 bar(a) / 485 °C, DN200 (193.7 mm), 60 m, K 82 t/h saturated at 4 bar(a), DN100 (102.3 mm), 200 m

Commercial steel 0.045 mm (Moody).

Results

The drop is 5–10 % of the inlet pressure: the inlet-density result understates the true drop by a few per cent; for a closer figure split the line into two or more sections.

Pressure drop35.665kPa
Pressure drop as a share of inlet pressure8.9163%
Velocity31.253m/s
Reynolds number503,169
Darcy friction factor0.017272
Steam density2.1627kg/m³
Steam viscosity0.013742cP

Download PDF CSV Link to this result Compare another case

Log in to save calculations to your dashboard.

Worked example

Example: 10 t/h saturated at 10.5 bar(a), DN150 (154.1 mm), 100 m, K 5. The inputs, in the units selected above:

InputValue
Steam flow10,000 kg/h
Steam pressure at the inlet (absolute)10.500 bar
Steam conditionDry saturated
Steam temperature (superheated only)250.00 °C
Pipe inside diameter154.10 mm
Pipe length100.00 m
Wall roughness0.045000 mm
Sum of fitting loss coefficients5.0000 -

Applying the formula below gives:

ResultValue
Pressure drop30.786 kPa
Pressure drop as a share of inlet pressure2.9320 %
Velocity27.628 m/s
Reynolds number1,524,608
Darcy friction factor0.015353
Steam density5.3907 kg/m³
Steam viscosity0.015054 cP

Open this example in the calculator and change any input.

Formula

\(u = \frac{4\,\dot m}{\rho\,\pi D^2} \qquad Re = \frac{\rho\,u\,D}{\mu} \qquad \Delta p = \left(f\,\frac{L}{D} + \Sigma K\right)\frac{\rho\,u^2}{2}\)

\(\frac{1}{\sqrt f} = -2\log_{10}\!\left(\frac{\varepsilon/D}{3.7} + \frac{2.51}{Re\sqrt f}\right)\)

Variables

Symbol Meaning SI unit
\(\dot m\) steam flow kg/s
\(p\) steam pressure at the inlet, absolute Pa
\(\text{state}\) dry saturated or superheated steam –
\(T_s\) steam temperature (superheated) K
\(D\) pipe inside diameter m
\(L\) pipe length m
\(\varepsilon\) wall roughness m
\(\Sigma K\) sum of fitting loss coefficients –
\(\Delta p\) pressure drop Pa
\(\Delta p / p\) pressure drop as a share of inlet pressure –
\(u\) velocity m/s
\(Re\) Reynolds number –
\(f\) Darcy friction factor –
\(\rho\) steam density kg/m³
\(\mu\) steam viscosity Pa·s

Method and standards

Darcy–Weisbach with the Colebrook–White friction factor, at the inlet steam state. Steam density from IAPWS-IF97 and viscosity from the IAPWS 2008 release, both FireCAD implementations.

Where it is used

  • Checking long steam mains and branches.
  • Choosing pipe size when pressure drop limits the line.
  • Estimating pressure at the far end of a distribution network.

Common mistakes

  • Using inlet density over a long line where pressure falls a lot.
  • Forgetting fittings and valves.
  • Using new-pipe roughness for old lines.

Assumptions and limits

  • Constant density along the line (inlet state): valid for drops up to about 10 % of the inlet pressure; between 5 and 10 % the page notes that the result is a few per cent low.
  • The velocity is compared with the speed of sound at the inlet (IF97); above Mach 0.3 the page warns that compressibility matters.
  • Dry steam; condensate in the line raises the drop.
  • No change of elevation (negligible for steam).

References

  • Darcy–Weisbach equation
  • Colebrook (1939)
  • IAPWS R7-97(2012) IF97
  • IAPWS 2008 (viscosity)

Questions and answers

How much pressure does a steam main lose?

10 t/h of saturated steam at 10.5 bar(a) in 100 m of DN150 pipe with fittings worth K = 5 loses 30.8 kPa, 2.9 % of the inlet pressure.

Is the density change along the pipe included?

No. The drop uses the inlet density. That is accurate while the drop is under about 10 % of the inlet pressure; above that the calculator warns, and the line should be split into sections.

Where do the steam properties come from?

Density from FireCAD's IAPWS-IF97 and viscosity from the IAPWS 2008 formulation, at the inlet pressure and temperature.

Method and article reviewed by FireCAD engineering on 10 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.

Related calculators

Free engineering calculators: every page computes in SI and converts to your units. Results are for engineering estimation; verify critical designs against the referenced standards.

Rejoining the server...

Rejoin failed... trying again in seconds.

Failed to rejoin.
Please retry or reload the page.

The session has been paused by the server.

Failed to resume the session.
Please retry or reload the page.