Worked example
Example: 10 t/h saturated at 10.5 bar(a), DN150 (154.1 mm), 100 m, K 5. The inputs, in the units selected above:
| Input | Value |
|---|---|
| Steam flow | 10,000 kg/h |
| Steam pressure at the inlet (absolute) | 10.500 bar |
| Steam condition | Dry saturated |
| Steam temperature (superheated only) | 250.00 °C |
| Pipe inside diameter | 154.10 mm |
| Pipe length | 100.00 m |
| Wall roughness | 0.045000 mm |
| Sum of fitting loss coefficients | 5.0000 - |
Applying the formula below gives:
| Result | Value |
|---|---|
| Pressure drop | 30.786 kPa |
| Pressure drop as a share of inlet pressure | 2.9320 % |
| Velocity | 27.628 m/s |
| Reynolds number | 1,524,608 |
| Darcy friction factor | 0.015353 |
| Steam density | 5.3907 kg/m³ |
| Steam viscosity | 0.015054 cP |
Open this example in the calculator and change any input.
Formula
\(u = \frac{4\,\dot m}{\rho\,\pi D^2} \qquad Re = \frac{\rho\,u\,D}{\mu} \qquad \Delta p = \left(f\,\frac{L}{D} + \Sigma K\right)\frac{\rho\,u^2}{2}\)
\(\frac{1}{\sqrt f} = -2\log_{10}\!\left(\frac{\varepsilon/D}{3.7} + \frac{2.51}{Re\sqrt f}\right)\)
Variables
| Symbol | Meaning | SI unit |
|---|---|---|
| \(\dot m\) | steam flow | kg/s |
| \(p\) | steam pressure at the inlet, absolute | Pa |
| \(\text{state}\) | dry saturated or superheated steam | – |
| \(T_s\) | steam temperature (superheated) | K |
| \(D\) | pipe inside diameter | m |
| \(L\) | pipe length | m |
| \(\varepsilon\) | wall roughness | m |
| \(\Sigma K\) | sum of fitting loss coefficients | – |
| \(\Delta p\) | pressure drop | Pa |
| \(\Delta p / p\) | pressure drop as a share of inlet pressure | – |
| \(u\) | velocity | m/s |
| \(Re\) | Reynolds number | – |
| \(f\) | Darcy friction factor | – |
| \(\rho\) | steam density | kg/m³ |
| \(\mu\) | steam viscosity | Pa·s |
Method and standards
Darcy–Weisbach with the Colebrook–White friction factor, at the inlet steam state. Steam density from IAPWS-IF97 and viscosity from the IAPWS 2008 release, both FireCAD implementations.
Where it is used
- Checking long steam mains and branches.
- Choosing pipe size when pressure drop limits the line.
- Estimating pressure at the far end of a distribution network.
Common mistakes
- Using inlet density over a long line where pressure falls a lot.
- Forgetting fittings and valves.
- Using new-pipe roughness for old lines.
Assumptions and limits
- Constant density along the line (inlet state): valid for drops up to about 10 % of the inlet pressure; between 5 and 10 % the page notes that the result is a few per cent low.
- The velocity is compared with the speed of sound at the inlet (IF97); above Mach 0.3 the page warns that compressibility matters.
- Dry steam; condensate in the line raises the drop.
- No change of elevation (negligible for steam).
References
- Darcy–Weisbach equation
- Colebrook (1939)
- IAPWS R7-97(2012) IF97
- IAPWS 2008 (viscosity)
Questions and answers
How much pressure does a steam main lose?
10 t/h of saturated steam at 10.5 bar(a) in 100 m of DN150 pipe with fittings worth K = 5 loses 30.8 kPa, 2.9 % of the inlet pressure.
Is the density change along the pipe included?
No. The drop uses the inlet density. That is accurate while the drop is under about 10 % of the inlet pressure; above that the calculator warns, and the line should be split into sections.
Where do the steam properties come from?
Density from FireCAD's IAPWS-IF97 and viscosity from the IAPWS 2008 formulation, at the inlet pressure and temperature.
Method and article reviewed by FireCAD engineering on 10 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.