FireCADCalc

Hydraulic Pressure Intensifier: Pressure and Flow

Outlet pressure and flow of a single-acting or reciprocating pressure intensifier from the inlet pressure, area ratio of the two pistons and efficiency.

Thermal power plantProcess steam and utilitiesSugar mill and cogenerationChemical and fertiliserPulp and paperFood, dairy and textile

Inputs

Examples: 100/40 mm at 100 barAir–oil 6 bar to 200 bar, 160/25 mm

Results

Force balance on the two pistons; leakage neglected in the flow. Rate all high-pressure components for the intensified pressure.

Area (intensification) ratio40.960
Outlet pressure174.63bar
Outlet flow0.48828L/min

Download PDF CSV Link to this result Compare another case

Log in to save calculations to your dashboard.

Worked example

Example: 100/40 mm at 100 bar. The inputs, in the units selected above:

InputValue
Inlet (low) pressure (absolute)100.00 bar
Large (low-pressure) piston diameter100.00 mm
Small (high-pressure) piston diameter40.000 mm
Inlet flow30.000 L/min
Mechanical efficiency90.000 %

Applying the formula below gives:

ResultValue
Area (intensification) ratio6.2500
Outlet pressure557.81 bar
Outlet flow4.8000 L/min

Open this example in the calculator and change any input.

Formula

\(p_2 - p_a = \eta (p_1 - p_a)\frac{A_1}{A_2}, \quad Q_2 = Q_1\frac{A_2}{A_1}\)

Variables

Symbol Meaning SI unit
\(p_1\) Inlet (low) pressure (absolute) Pa
\(D_1\) Large (low-pressure) piston diameter m
\(D_2\) Small (high-pressure) piston diameter m
\(Q_1\) Inlet flow m³/s
\(\eta\) Mechanical efficiency -
\(p_a\) Atmospheric pressure, 101 325 Pa Pa
\(A_1/A_2\) Area (intensification) ratio -
\(p_2\) Outlet pressure Pa
\(Q_2\) Outlet flow m³/s

Method and standards

Force and volume balance.

Where it is used

  • Hydraulic clamping and test benches.
  • Air-over-oil boosters.

Common mistakes

  • Ignoring efficiency at high ratios.
  • Forgetting the pressure rating of downstream parts.

Assumptions and limits

  • No leakage.
  • Pressures absolute; the backs of both pistons are vented to atmosphere (p_a = 101 325 Pa), so the intensification applies to gauge pressure.

References

  • Force balance on stepped pistons (definitions)

Questions and answers

How does an intensifier raise pressure?

The same force acts on a smaller area: pressure rises by the area ratio, flow falls by it.

Where are they used?

Clamping, test rigs, presses and water-jet cutting, where a small flow at high pressure is needed from a low-pressure supply.

What do the defaults represent?

A 100 mm/40 mm intensifier fed at 100 bar and 30 L/min.

Method and article reviewed by FireCAD engineering on 13 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.

Related calculators

Free engineering calculators: every page computes in SI and converts to your units. Results are for engineering estimation; verify critical designs against the referenced standards.