Hydraulic System Heat Load and Oil Cooler Duty

Heat generated in a hydraulic system from input power and efficiency, reservoir heat loss, oil cooler duty and the warm-up rate without cooling.

Thermal power plantProcess steam and utilitiesSugar mill and cogenerationChemical and fertiliserPulp and paperFood, dairy and textile

Inputs

Examples: 30 kW unit at 70 %Press 75 kW at 60 %

Results

Every watt not delivered as useful work becomes heat in the oil. Warm-up rate uses the oil ρc_p entered and ignores the steel. Size the cooler at the hottest ambient.

Heat generated30.000kW
Heat lost by the reservoir0.60000kW
Cooler duty needed29.400kW
Warm-up rate without cooler1.0889K/min

Download PDF CSV Link to this result Compare another case

Log in to save calculations to your dashboard.

Worked example

Example: 30 kW unit at 70 %. The inputs, in the units selected above:

InputValue
Pump input power30.000 kW
Overall system efficiency (useful work/input)70.000 %
Reservoir heat-losing area3.0000 m²
Reservoir coefficient to air12.000 W/(m²·K)
Allowed oil temperature55.000 °C
Ambient temperature35.000 °C
Oil density870.00 kg/m³
Oil specific heat1.9000 kJ/(kg·K)
Oil volume in the system400.00 L

Applying the formula below gives:

ResultValue
Heat generated9.0000 kW
Heat lost by the reservoir0.72000 kW
Cooler duty needed8.2800 kW
Warm-up rate without cooler0.81670 K/min

Open this example in the calculator and change any input.

Formula

\(Q = P_{in}(1 - \eta), \quad Q_r = UA_r(T_{oil} - T_a), \quad Q_c = \max(Q - Q_r,\ 0), \quad \frac{dT}{dt} = \frac{Q}{V\rho_o c_{p,o}}\)

Variables

Symbol Meaning SI unit
\(P_{in}\) Pump input power W
\(\eta\) Overall system efficiency (useful work/input) -
\(A_r\) Reservoir heat-losing area m²
\(U\) Reservoir coefficient to air W/(m²·K)
\(T_{oil}\) Allowed oil temperature K
\(T_a\) Ambient temperature K
\(\rho_o\) Oil density kg/m³
\(c_{p,o}\) Oil specific heat J/(kg·K)
\(V\) Oil volume in the system m³
\(Q\) Heat generated W
\(Q_r\) Heat lost by the reservoir W
\(Q_c\) Cooler duty needed W
\(dT/dt\) Warm-up rate without cooler, in K/min K/min

Method and standards

Energy balance.

Where it is used

  • Oil cooler selection.
  • Diagnosing overheating systems.

Common mistakes

  • Sizing at mild ambient.
  • Ignoring relief-valve flow in fixed pumps.

Assumptions and limits

  • Steady state; the warm-up rate ignores the heat capacity of the steel and is shown in K/min in every unit system.

References

  • Energy balance of a hydraulic system (definitions)

Questions and answers

Where does the heat come from?

Pump and motor losses, throttling in valves and relief flow; a system at 70 % efficiency turns 30 % of its input into heat.

Can the reservoir alone do the cooling?

Only for small or lightly used systems; reservoirs lose roughly 10–15 W/(m²·K).

What do the defaults represent?

A 30 kW power unit at 70 % efficiency with a 3 m² reservoir in 35 °C ambient.

Method and article reviewed by FireCAD engineering on 13 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.

Related calculators

Free engineering calculators: every page computes in SI and converts to your units. Results are for engineering estimation; verify critical designs against the referenced standards.

Rejoining the server...

Rejoin failed... trying again in seconds.

Failed to rejoin.
Please retry or reload the page.

The session has been paused by the server.

Failed to resume the session.
Please retry or reload the page.