Worked example
Example: Illustrative 10 m3/s, 1500 Pa, 1480 rpm, 0.9 m. The inputs, in the units selected above:
| Input | Value |
|---|---|
| Volume flow | 36,000 m³/h |
| Fan total pressure rise | 152.96 mmWC |
| Gas density | 1.2000 kg/m³ |
| Rotational speed | 1,480.0 rpm |
| Impeller diameter | 0.90000 m |
Applying the formula below gives:
| Result | Value |
|---|---|
| Specific speed ω√Q/(Δp/ρ)^¾ | 2.3314 |
| Specific diameter D(Δp/ρ)^¼/√Q | 1.6923 |
| Flow coefficient Q/(nD³) | 0.55611 |
| Pressure coefficient Δp/(ρn²D²) | 2.5363 |
| Tip speed | 69.743 m/s |
Open this example in the calculator and change any input.
Formula
\(\omega_s = \frac{\omega\sqrt Q}{(\Delta p/\rho)^{3/4}}, \quad D_s = \frac{D(\Delta p/\rho)^{1/4}}{\sqrt Q}, \quad \varphi = \frac{Q}{nD^3}, \quad \psi = \frac{\Delta p}{\rho n^2D^2}\)
Variables
| Symbol | Meaning | SI unit |
|---|---|---|
| \(Q\) | Volume flow | m³/s |
| \(\Delta p_t\) | Fan total pressure rise | Pa |
| \(\rho\) | Gas density | kg/m³ |
| \(n\) | Rotational speed | rad/s |
| \(D\) | Impeller diameter | m |
| \(\omega_s\) | Specific speed ω√Q/(Δp/ρ)^¾ | - |
| \(D_s\) | Specific diameter D(Δp/ρ)^¼/√Q | - |
| \(\varphi\) | Flow coefficient Q/(nD³) | - |
| \(\psi\) | Pressure coefficient Δp/(ρn²D²) | - |
| \(u\) | Tip speed | m/s |
Method and standards
Turbomachine similarity.
Where it is used
- Fan selection and comparison.
- Scaling test data to other sizes.
Common mistakes
- Mixing rpm and rad/s.
- Using static instead of total pressure.
Assumptions and limits
- Incompressible flow.
References
- Similarity parameters of turbomachines
Questions and answers
Why use specific speed?
It combines flow, pressure and speed into one number that is the same for geometrically similar fans, so it shows which fan type suits a duty.
What does the pressure coefficient show?
How hard the impeller works for its tip speed; backward-curved centrifugal fans have high ψ, axial fans low ψ.
What do the defaults represent?
An illustrative 10 m³/s at 1,500 Pa total pressure, air at 1.2 kg/m³, 1,480 rpm and a 0.9 m impeller.
Method and article reviewed by FireCAD engineering on 17 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.
Sources
Bleier, Fan Handbook: Selection, Application and Design (McGraw-Hill, 1998)