FireCADCalc

Induction Furnace Melting Energy and Power

Specific energy to heat, melt and superheat a metal charge, the heat into the metal and the electrical power and energy per tonne for a melt rate and efficiency.

Inputs

Examples: Illustrative 5 t/h steel meltGrey iron 3 t/hAluminium 1 t/h

Accepted: 0.00036 to 360 t/h
Accepted: 0.1 to 3 kJ/(kg·K)
Accepted: -73.15 to 1,226.8 °C
Accepted: 26.85 to 3,226.8 °C
Accepted: 0 to 2,000 kJ/kg
Accepted: 0.1 to 3 kJ/(kg·K)
Accepted: 26.85 to 3,726.8 °C
Accepted: 5 to 100 %

Results

The metal needs sensible heat to the melting point, the latent heat of fusion and superheat to the tapping temperature: q = c̄_s(T_m − T₀) + L_f + c_l(T_t − T_m), about 370–390 kWh/t for steel tapped at 1,600 °C and about 340 kWh/t for grey iron at 1,500 °C. Coil losses, refractory and radiation losses and holding time lower the overall efficiency to roughly 60–75 % for coreless furnaces, so plants see 520–650 kWh/t at the meter.

Heat into the metal per tonne324.99kWh/t
Heat rate into the metal324.99kW
Electrical power590.88kW
Electrical energy per tonne590.88kWh/t

Download PDF CSV Link to this result Compare another case

Log in to save calculations to your dashboard.

Worked example

Example: Illustrative 5 t/h steel melt. The inputs, in the units selected above:

InputValue
Melt rate5.0000 t/h
Mean specific heat of the solid0.68000 kJ/(kg·K)
Charge temperature25.000 °C
Melting temperature1,500.0 °C
Latent heat of fusion270.00 kJ/kg
Specific heat of the liquid0.82000 kJ/(kg·K)
Tapping temperature1,600.0 °C
Overall efficiency (electrical × thermal)70.000 %

Applying the formula below gives:

ResultValue
Heat into the metal per tonne376.39 kWh/t
Heat rate into the metal1,881.9 kW
Electrical power2,688.5 kW
Electrical energy per tonne537.70 kWh/t

Open this example in the calculator and change any input.

Formula

\(q = \bar c_s(T_m - T_0) + L_f + c_l(T_t - T_m), \quad P_e = \frac{\dot mq}{\eta}\)

Variables

Symbol Meaning SI unit
\(\dot m\) Melt rate kg/s
\(\bar c_s\) Mean specific heat of the solid J/(kg·K)
\(T_0\) Charge temperature K
\(T_m\) Melting temperature K
\(L_f\) Latent heat of fusion J/kg
\(c_l\) Specific heat of the liquid J/(kg·K)
\(T_t\) Tapping temperature K
\(\eta\) Overall efficiency (electrical × thermal) -
\(q\) Heat into the metal per tonne J/kg
\(P_m\) Heat rate into the metal W
\(P_e\) Electrical power W
\(q_e\) Electrical energy per tonne J/kg

Method and standards

Melting energy.

Where it is used

  • Sizing induction furnaces and power supplies.
  • Benchmarking foundry energy use.

Common mistakes

  • Forgetting superheat and holding.
  • Using the liquid specific heat for the solid range.

Assumptions and limits

  • Steady melt rate; mean properties; losses lumped in the efficiency.

References

  • Heat balance of a melting furnace

Questions and answers

Why is the meter energy so much higher than the metal's heat?

Coil I²R losses, cooling water, refractory and radiation losses and holding time all draw power.

What mean specific heat should I use for steel?

About 0.65–0.70 kJ/kg·K from room temperature to the melting point, which includes the phase changes in the solid.

What do the defaults represent?

An illustrative 5 t/h steel melt from 25 °C, melting at 1,500 °C, tapped at 1,600 °C, 70 % overall efficiency.

Method and article reviewed by FireCAD engineering on 17 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.

Sources

Rudnev, Loveless and Cook, Handbook of Induction Heating, 2nd ed. (CRC Press, 2017)

Related calculators

Free engineering calculators: every page computes in SI and converts to your units. Results are for engineering estimation; verify critical designs against the referenced standards.

Rejoining the server...

Rejoin failed... trying again in seconds.

Failed to rejoin.
Please retry or reload the page.

The session has been paused by the server.

Failed to resume the session.
Please retry or reload the page.