FireCADCalc

Zener–Hollomon Parameter and Hot Working Flow Stress

Zener–Hollomon parameter from strain rate and temperature, and steady hot working flow stress by the Sellars–Tegart hyperbolic sine law.

Inputs

Examples: Illustrative 1000 C at 1 per sFinishing 900 C at 10 per sSlow forging 1150 C at 0.1 per s

Accepted: 1E-5 to 10,000 1/s
Accepted: 226.85 to 1,426.8 °C
Accepted: 100 to 600 kJ/mol
Accepted: 1 to 1E+20
Accepted: 0.001 to 0.1
Accepted: 2 to 10

Results

Z = ε̇·exp(Q/RT); σ = (1/α)·asinh((Z/A)^(1/n)). A, α, n and Q are fitted to hot compression or torsion tests for each alloy; the defaults are illustrative for a carbon-manganese steel in austenite.

Zener–Hollomon parameter (1/s)7.7905e+14
ln Z34.289
Steady flow stress207.68MPa

Download PDF CSV Link to this result Compare another case

Log in to save calculations to your dashboard.

Worked example

Example: Illustrative 1000 C at 1 per s. The inputs, in the units selected above:

InputValue
Strain rate1.0000 1/s
Deformation temperature1,000.0 °C
Activation energy for deformation312.00 kJ/mol
Constant A (1/s)1.0000e+11 -
Stress multiplier (1/MPa)0.012000 -
Stress exponent5.0000 -

Applying the formula below gives:

ResultValue
Zener–Hollomon parameter (1/s)6.3161e+12
ln Z29.474
Steady flow stress130.57 MPa

Open this example in the calculator and change any input.

Formula

\(Z = \dot\varepsilon\exp\frac{Q}{RT}, \quad \sigma = \frac1\alpha\sinh^{-1}\left[\left(\frac ZA\right)^{1/n}\right]\)

Variables

Symbol Meaning SI unit
\(\dot\varepsilon\) Strain rate 1/s
\(T\) Deformation temperature K
\(Q\) Activation energy for deformation J/mol
\(A\) Constant A (1/s) -
\(\alpha\) Stress multiplier (1/MPa) -
\(n\) Stress exponent -
\(Z\) Zener–Hollomon parameter (1/s) -
\(\ln Z\) ln Z -
\(\sigma\) Steady flow stress Pa

Method and standards

Hot working law.

Where it is used

  • Rolling and forging load estimates.
  • Process window studies.

Common mistakes

  • Mixing MPa and Pa in α.
  • Using constants outside the fitted range.

Assumptions and limits

  • Steady-state flow; constant structure.

References

  • Sellars–Tegart constitutive law

Questions and answers

What does the Zener–Hollomon parameter combine?

Strain rate and temperature into one number: fast, cold deformation gives high Z and high flow stress.

Why does Z matter for microstructure?

Recrystallised grain size after hot working falls as Z rises, so Z links mill settings to final properties.

What do the defaults represent?

Illustrative carbon-manganese steel constants (Q 312 kJ/mol, A 10¹¹ s⁻¹, α 0.012 MPa⁻¹, n 5) at 1,000 °C and 1 s⁻¹.

Method and article reviewed by FireCAD engineering on 17 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.

Sources

Dieter, Mechanical Metallurgy, 3rd ed. (McGraw-Hill, 1986), ch. 15

Related calculators

Free engineering calculators: every page computes in SI and converts to your units. Results are for engineering estimation; verify critical designs against the referenced standards.

Rejoining the server...

Rejoin failed... trying again in seconds.

Failed to rejoin.
Please retry or reload the page.

The session has been paused by the server.

Failed to resume the session.
Please retry or reload the page.