Recrystallisation Kinetics by the JMAK (Avrami) Equation

Fraction recrystallised after a time at temperature by the Johnson–Mehl–Avrami–Kolmogorov equation, with the half time shifted by an activation energy.

Inputs

Examples: Illustrative 620 C for 5 hLower 580 C for 20 hFast 700 C, n = 3

Accepted: 0.00016667 to 166,670 min
Accepted: 26.85 to 1,426.8 °C
Accepted: 20 to 500 kJ/mol
Accepted: 26.85 to 1,426.8 °C
Accepted: 0.5 to 4
Accepted: 0.00016667 to 1,666,700 min
Accepted: 1 to 99.9 %

Results

X = 1 − exp(−k·tⁿ), k = ln 2/t₅₀ⁿ; t₅₀ scales with exp(Q/RT). Fit t₅₀ and n to annealing tests on the same cold-worked material; prior strain and grain size change both.

Half time at the annealing temperature1,144.5min
Fraction recrystallised53.325%
Time for the target fraction2,086.0min

Download PDF CSV Link to this result Compare another case

Log in to save calculations to your dashboard.

Worked example

Example: Illustrative 620 C for 5 h. The inputs, in the units selected above:

InputValue
Half time at the reference temperature600.00 min
Reference temperature600.00 °C
Activation energy200.00 kJ/mol
Annealing temperature620.00 °C
Avrami exponent2.0000 -
Annealing time300.00 min
Target fraction95.000 %

Applying the formula below gives:

ResultValue
Half time at the annealing temperature323.77 min
Fraction recrystallised44.850 %
Time for the target fraction673.09 min

Open this example in the calculator and change any input.

Formula

\(X = 1 - \exp(-kt^n), \quad k = \frac{\ln2}{t_{50}^n}, \quad t_{50} = t_{50,ref}\exp\left[\frac QR\left(\frac1T - \frac1{T_{ref}}\right)\right]\)

Variables

Symbol Meaning SI unit
\(t_{50,ref}\) Half time at the reference temperature s
\(T_{ref}\) Reference temperature K
\(Q\) Activation energy J/mol
\(T\) Annealing temperature K
\(n\) Avrami exponent -
\(t\) Annealing time s
\(X_t\) Target fraction -
\(t_{50}\) Half time at the annealing temperature s
\(X\) Fraction recrystallised -
\(t_X\) Time for the target fraction s

Method and standards

JMAK kinetics.

Where it is used

  • Annealing cycle design.
  • Batch and continuous annealing studies.

Common mistakes

  • Using a single n for very different strains.
  • Extrapolating far beyond tested temperatures.

Assumptions and limits

  • Isothermal annealing; site-saturated or constant nucleation.

References

  • Johnson–Mehl–Avrami–Kolmogorov kinetics

Questions and answers

Why the S-shaped curve?

New grains first nucleate slowly, then grow quickly, then run out of deformed material and impinge on each other.

How sensitive is it to temperature?

Very: with Q = 200 kJ/mol, 20 K hotter near 600 °C roughly halves the time.

What do the defaults represent?

An illustrative cold-worked alloy with a 10-hour half time at 600 °C, Q = 200 kJ/mol, annealed at 620 °C for 5 hours, n = 2.

Method and article reviewed by FireCAD engineering on 17 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.

Sources

Humphreys and Hatherly, Recrystallization and Related Annealing Phenomena, 2nd ed. (Elsevier, 2004), ch. 7

Related calculators

Free engineering calculators: every page computes in SI and converts to your units. Results are for engineering estimation; verify critical designs against the referenced standards.

Rejoining the server...

Rejoin failed... trying again in seconds.

Failed to rejoin.
Please retry or reload the page.

The session has been paused by the server.

Failed to resume the session.
Please retry or reload the page.