Furnace Carbon Activity and Carbon Potential from CO and CO₂

Carbon activity of a furnace atmosphere from CO and CO₂ partial pressures via the Boudouard equilibrium, and the equivalent carbon content in austenite.

Thermal power plantProcess steam and utilitiesRefinery and petrochemical

Inputs

Examples: Illustrative endogas at 925 CLean atmosphere at 850 CSooting risk at 950 C

Accepted: 0.001 to 200 kPa
Accepted: 1E-5 to 200 kPa
Accepted: 626.85 to 1,126.8 °C
Accepted: 100 to 250 kJ/mol
Accepted: 100 to 250
Accepted: 0.3 to 2.5 %

Results

C + CO₂ ⇌ 2CO: K = (p_CO/p°)²/[a_C(p_CO₂/p°)], so a_C = p_CO²/(K·p_CO₂·p°). ΔG° = ΔH° − TΔS° uses 298 K standard data (Ellingham approximation, editable). Carbon potential ≈ a_C·C_sat assumes Henrian behaviour of carbon in austenite; real atmospheres are controlled from dew point or O₂ probes calibrated against shim stock. a_C above 1 means sooting.

Standard free energy-42.568kJ/mol
Equilibrium constant65.737
Carbon activity1.8407
Carbon potential (approximate)1.3500%

Download PDF CSV Link to this result Compare another case

Log in to save calculations to your dashboard.

Worked example

Example: Illustrative endogas at 925 C. The inputs, in the units selected above:

InputValue
CO partial pressure20.000 kPa
CO₂ partial pressure0.15000 kPa
Furnace temperature925.00 °C
Reaction enthalpy (C + CO₂ → 2CO)172.45 kJ/mol
Reaction entropy (J/(mol·K))175.79 -
Carbon in austenite at graphite saturation1.2500 %

Applying the formula below gives:

ResultValue
Standard free energy-38.173 kJ/mol
Equilibrium constant46.148
Carbon activity0.57785
Carbon potential (approximate)0.72232 %

Open this example in the calculator and change any input.

Formula

\(a_C = \frac{(p_{CO}/p^\circ)^2}{K\,(p_{CO_2}/p^\circ)}, \quad K = e^{-\Delta G^\circ/RT}, \quad \Delta G^\circ = \Delta H^\circ - T\Delta S^\circ, \quad C_p \approx a_CC_{sat}\)

Variables

Symbol Meaning SI unit
\(p_{CO}\) CO partial pressure Pa
\(p_{CO_2}\) CO₂ partial pressure Pa
\(T\) Furnace temperature K
\(\Delta H^\circ\) Reaction enthalpy (C + CO₂ → 2CO) J/mol
\(\Delta S^\circ\) Reaction entropy (J/(mol·K)) -
\(C_{sat}\) Carbon in austenite at graphite saturation -
\(\Delta G^\circ\) Standard free energy J/mol
\(K\) Equilibrium constant -
\(a_C\) Carbon activity -
\(C_p\) Carbon potential (approximate) -

Method and standards

Carbon potential.

Where it is used

  • Carburising and hardening atmosphere control.
  • Avoiding decarburisation or sooting.

Common mistakes

  • Using the CO/CO₂ ratio without temperature.
  • Treating the Henrian estimate as exact at high carbon.

Assumptions and limits

  • Ideal gases; Ellingham approximation; Henrian carbon in austenite.

References

  • Boudouard equilibrium with 298 K standard data
  • NIST Chemistry WebBook
  • standard enthalpies of formation and entropies (CO, CO₂, graphite)

Questions and answers

Why does carbon potential fall at higher temperature for the same gas?

The Boudouard reaction favours CO at high temperature, so the same CO/CO₂ ratio means a lower carbon activity.

How is carbon potential controlled in practice?

By trimming enriching gas or air against an oxygen probe or dew point, with the relation checked by shim stock analysis.

What do the defaults represent?

An illustrative endothermic-type atmosphere with 20 kPa CO and 150 Pa CO₂ at 925 °C, graphite-saturated austenite at 1.25 % C.

Method and article reviewed by FireCAD engineering on 17 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.

Sources

Gaskell, Introduction to the Thermodynamics of Materials, 5th ed. (Taylor & Francis, 2008)

Related calculators

Free engineering calculators: every page computes in SI and converts to your units. Results are for engineering estimation; verify critical designs against the referenced standards.

Rejoining the server...

Rejoin failed... trying again in seconds.

Failed to rejoin.
Please retry or reload the page.

The session has been paused by the server.

Failed to resume the session.
Please retry or reload the page.