FireCADCalc

Corrosion Current from Tafel Extrapolation

Corrosion current density by extrapolating a measured current at an overpotential back along a Tafel line, and the corrosion rate by Faraday's law.

Thermal power plantProcess steam and utilitiesSugar mill and cogenerationRefinery and petrochemicalChemical and fertiliserPulp and paper

Inputs

Examples: Iron, 500 µA/cm² at 150 mV, 120 mV/decZinc, 80 µA/cm² at 100 mV, 60 mV/dec

Results

Valid only on the linear (Tafel) part of the E–log i curve, usually more than 50 mV from E_corr. Concentration polarisation on the cathodic branch makes the extrapolation unreliable.

Corrosion current density (µA/cm²)1.7235
Corrosion rate (mm/year)0.025810

Download PDF CSV Link to this result Compare another case

Log in to save calculations to your dashboard.

Worked example

Example: Iron, 500 µA/cm² at 150 mV, 120 mV/dec. The inputs, in the units selected above:

InputValue
Measured current density on the Tafel line (µA/cm²)500.00 -
Overpotential from E_corr (mV)150.00 -
Tafel slope of that branch (mV/decade)120.00 -
Equivalent weight (g per equivalent)27.920 kg/kmol
Metal density7,870.0 kg/m³

Applying the formula below gives:

ResultValue
Corrosion current density (µA/cm²)28.117
Corrosion rate (mm/year)0.32625

Open this example in the calculator and change any input.

Formula

\(i_{corr} = \frac{i}{10^{|\eta|/\beta}}, \quad CR = \frac{i_{corr}EW}{F\rho}\)

Variables

Symbol Meaning SI unit
\(i\) Measured current density on the Tafel line (µA/cm²) -
\(|\eta|\) Overpotential from E_corr (mV) -
\(\beta\) Tafel slope of that branch (mV/decade) -
\(EW\) Equivalent weight (g per equivalent) kg/kmol
\(\rho\) Metal density kg/m³
\(i_{corr}\) Corrosion current density (µA/cm²) -
\(CR\) Corrosion rate (mm/year) -

Method and standards

Tafel equation.

Where it is used

  • Laboratory corrosion tests.
  • Comparing inhibitors.

Common mistakes

  • Using points too near E_corr.
  • Ignoring IR drop.

Assumptions and limits

  • Activation-controlled branch.
  • Current densities are plain numbers in µA/cm², the overpotential in mV and the Tafel slope in mV/decade, in every unit system; the corrosion rate is in mm/year (1 mm/year = 39.4 mpy).

References

  • Tafel equation η = β log(i/i_corr); Faraday's law per ASTM G102; Jones
  • Principles and Prevention of Corrosion
  • 2nd ed. (Prentice Hall, 1996)

Questions and answers

Why extrapolate?

At E_corr the anodic and cathodic currents cancel; the corrosion current is found by extending a Tafel line back to E_corr.

Which branch should I use?

The cleaner linear branch, often the cathodic one in deaerated acid, the anodic one where oxygen diffusion controls.

What do the defaults represent?

A point 150 mV from E_corr at 500 µA/cm² on a 120 mV/decade branch, for iron.

Method and article reviewed by FireCAD engineering on 13 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.

Related calculators

Free engineering calculators: every page computes in SI and converts to your units. Results are for engineering estimation; verify critical designs against the referenced standards.

Rejoining the server...

Rejoin failed... trying again in seconds.

Failed to rejoin.
Please retry or reload the page.

The session has been paused by the server.

Failed to resume the session.
Please retry or reload the page.