Worked example
Example: 12.7 to 10.9 mm in 6 years, minimum 7.2 mm. The inputs, in the units selected above:
| Input | Value |
|---|---|
| Earlier thickness reading (or original thickness) | 12.700 mm |
| Latest thickness reading | 10.900 mm |
| Years between the readings | 6.0000 - |
| Minimum required thickness | 7.2000 mm |
Applying the formula below gives:
| Result | Value |
|---|---|
| Corrosion rate (mm per year) | 0.30000 |
| Corrosion rate (mils per year) | 11.811 |
| Remaining life (years) | 12.333 |
| Metal lost between the readings | 1.8000 mm |
Open this example in the calculator and change any input.
Formula
\(CR = \frac{t_1 - t_2}{\Delta y} \qquad CR_{mpy} = \frac{CR}{0.0254} \qquad RL = \frac{t_2 - t_{min}}{CR} \qquad \Delta t = t_1 - t_2\)
Variables
| Symbol | Meaning | SI unit |
|---|---|---|
| \(t_1\) | earlier thickness | m |
| \(t_2\) | latest thickness | m |
| \(\Delta y\) | years between | years |
| \(t_{min}\) | minimum required thickness | m |
| \(CR\) | corrosion rate | mm/y |
| \(CR_{mpy}\) | corrosion rate | mils/y |
| \(RL\) | remaining life | years |
| \(\Delta t\) | metal lost | m |
Method and standards
Linear corrosion between readings at the same location; 1 mil = 0.0254 mm.
Where it is used
- Boiler tube and drum surveys.
- Tank and pipe inspection.
- Planning replacements.
Common mistakes
- Comparing readings at different spots.
- Ignoring measurement scatter (±0.1–0.2 mm).
- Assuming the rate stays constant after a change in service.
Assumptions and limits
- Uniform corrosion; pitting needs other methods.
- The remaining life has no safety factor. Inspection codes usually set the next inspection at a fraction of the remaining life (often half); follow the code that applies to the equipment.
References
- Thickness-based corrosion rate (inspection practice)
Questions and answers
What is the rate if 12.7 mm fell to 10.9 mm in 6 years?
0.30 mm/y (11.8 mpy); with a 7.2 mm minimum, 12.3 years of life remain.
Long-term or short-term rate?
Use both, and plan on the higher.
Where does the minimum thickness come from?
From the design code calculation for pressure and structural loads.
Method and article reviewed by FireCAD engineering on 12 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.