Worked example
Example: Carbon steel, 120/120 mV, 2 kΩ·cm². The inputs, in the units selected above:
| Input | Value |
|---|---|
| Anodic Tafel slope (mV/decade) | 120.00 - |
| Cathodic Tafel slope (mV/decade) | 120.00 - |
| Polarisation resistance (Ω·cm²) | 2,000.0 - |
| Equivalent weight (g per equivalent) | 27.920 kg/kmol |
| Metal density | 7,870.0 kg/m³ |
Applying the formula below gives:
| Result | Value |
|---|---|
| Stern–Geary constant (mV) | 26.058 |
| Corrosion current density (µA/cm²) | 13.029 |
| Corrosion rate (mm/year) | 0.15118 |
Open this example in the calculator and change any input.
Formula
\(B = \frac{\beta_a\beta_c}{2.303(\beta_a + \beta_c)}, \quad i_{corr} = \frac{B}{R_p}, \quad CR = \frac{i_{corr}EW}{F\rho}\)
Variables
| Symbol | Meaning | SI unit |
|---|---|---|
| \(\beta_a\) | Anodic Tafel slope (mV/decade) | - |
| \(\beta_c\) | Cathodic Tafel slope (mV/decade) | - |
| \(R_p\) | Polarisation resistance (Ω·cm²) | - |
| \(EW\) | Equivalent weight (g per equivalent) | kg/kmol |
| \(\rho\) | Metal density | kg/m³ |
| \(B\) | Stern–Geary constant (mV) | - |
| \(i_{corr}\) | Corrosion current density (µA/cm²) | - |
| \(CR\) | Corrosion rate (mm/year) | - |
Method and standards
Stern–Geary and Faraday.
Where it is used
- Cooling water and process corrosion monitoring.
- Inhibitor trials.
Common mistakes
- Mixing Ω and Ω·cm².
- Using LPR in low-conductivity water.
Assumptions and limits
- Uniform corrosion; activation control.
- Faraday constant from CODATA (96 485.332 12 C/mol). Tafel slopes, R_p, B, i_corr and CR are entered and shown in the units named in their labels (mV/decade, Ω·cm², mV, µA/cm², mm/year), not converted by the unit lists.
References
- Stern and Geary (1957); ASTM G59 and G102 (Faraday's-law conversion to penetration rate); Jones
- Principles and Prevention of Corrosion
- 2nd ed. (Prentice Hall, 1996)
Questions and answers
What is a corrosion rate of 0.1 mm/y?
Moderate for carbon steel in cooling water; many systems aim for less than 0.075 mm/y (3 mpy).
Where do Tafel slopes come from?
From a potentiodynamic scan, or literature values for the metal and environment.
What do the defaults represent?
Carbon steel with 120 mV/decade slopes and 2 kΩ·cm² polarisation resistance.
Method and article reviewed by FireCAD engineering on 13 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.