FireCADCalc

Proximity Probe Gap, Shaft Vibration and Frequency

Probe gap from the DC gap voltage, peak-to-peak shaft displacement from the AC signal, the running-speed frequency and the margin within the linear range.

Inputs

Examples: Illustrative probe at -10 VGap set too closeSlow fan bearing

Accepted: 0.1 to 24 V
Accepted: 0.1 to 20
Accepted: 0 to 20 V
Accepted: 9.5493 to 28,648 rpm
Accepted: 0.1 to 20 mm
Accepted: 0 to 10 mm

Results

An eddy-current probe system gives a DC voltage proportional to gap (typically 7.87 V/mm, i.e. 200 mV/mil, with −24 V supply) and an AC part from shaft vibration. Gap = |V_gap|/S, displacement = V_pp/S. Set the gap near the middle of the linear range (about −10 V) so the vibration and thermal growth stay inside it. Sensitivity depends on target material; 4140 steel is the usual calibration target.

Probe gap1.1436mm
Shaft displacement peak to peak114.36µm
Running-speed frequency12.333Hz
Margin to the linear range limit0.89358mm
Vibration within range (1 = yes)1.0000

Download PDF CSV Link to this result Compare another case

Log in to save calculations to your dashboard.

Worked example

Example: Illustrative probe at -10 V. The inputs, in the units selected above:

InputValue
DC gap voltage (magnitude)10.000 V
Probe sensitivity (V per mm)7.8700 -
AC signal peak to peak0.40000 V
Shaft speed3,000.0 rpm
End of linear range (gap)2.2900 mm
Start of linear range (gap)0.25000 mm

Applying the formula below gives:

ResultValue
Probe gap1.2706 mm
Shaft displacement peak to peak50.826 µm
Running-speed frequency50.000 Hz
Margin to the linear range limit1.0194 mm
Vibration within range (1 = yes)1.0000

Open this example in the calculator and change any input.

Formula

\(g = \frac{|V_{gap}|}{S}, \quad x_{pp} = \frac{V_{pp}}{S}, \quad f = \frac{n}{60}\)

Variables

Symbol Meaning SI unit
\(V_{gap}\) DC gap voltage (magnitude) V
\(S\) Probe sensitivity (V per mm) -
\(V_{pp}\) AC signal peak to peak V
\(n\) Shaft speed rad/s
\(g_{max}\) End of linear range (gap) m
\(g_{min}\) Start of linear range (gap) m
\(g\) Probe gap m
\(x_{pp}\) Shaft displacement peak to peak m
\(f_{1\times}\) Running-speed frequency 1/s
\(\min(g - g_{min}, g_{max} - g)\) Margin to the linear range limit m
\(x_{pp}/2 \le margin\) Vibration within range (1 = yes) -

Method and standards

Proximity probe.

Where it is used

  • Turbine and compressor vibration monitoring.
  • Gap setting during installation.

Common mistakes

  • Using mils and millimetres together.
  • Setting the gap near the end of the linear range.

Assumptions and limits

  • Linear probe response; calibrated target material.

References

  • Eddy-current displacement probe scaling

Questions and answers

Why set the gap at about −10 V?

It is near the middle of the linear range, leaving room for vibration and thermal or bearing movement.

Does shaft material matter?

Yes: sensitivity is calibrated for a particular steel; other materials change the scale factor.

What do the defaults represent?

An illustrative 8 mm probe system at 7.87 V/mm reading −10.0 V gap and 0.40 V peak to peak at 3,000 rpm.

Method and article reviewed by FireCAD engineering on 17 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.

Sources

Bently and Hatch, Fundamentals of Rotating Machinery Diagnostics (Bently Pressurized Bearing Press, 2002), Lipták (ed.), Instrument Engineers' Handbook, Vol. 1: Process Measurement and Analysis, 4th ed. (CRC Press, 2003)

Related calculators

Free engineering calculators: every page computes in SI and converts to your units. Results are for engineering estimation; verify critical designs against the referenced standards.

Rejoining the server...

Rejoin failed... trying again in seconds.

Failed to rejoin.
Please retry or reload the page.

The session has been paused by the server.

Failed to resume the session.
Please retry or reload the page.