500 µε = 0.0005.

Results

Half and full bridges with opposite strains are linear and compensate temperature; the quarter bridge is not.

Half and full bridge outputs assume the active gauges see equal and opposite strain (bending). For axial loading with Poisson gauges the output is smaller: GF ε (1 + ν)/4 × V_ex for a half bridge and GF ε (1 + ν)/2 × V_ex for a full bridge.

Bridge output-2.5000mV
Linear approximation-2.5000mV
Non-linearity (exact vs linear)0%

Download PDF CSV Link to this result Compare another case

Log in to save calculations to your dashboard.

Worked example

Example: Quarter bridge, 500 µε, 5 V. The inputs, in the units selected above:

InputValue
Gauge factor2.0000 -
Strain5.0000e-04 -
Excitation voltage5.0000 V
ArrangementQuarter bridge (one active gauge)

Applying the formula below gives:

ResultValue
Bridge output1.2494 mV
Linear approximation1.2500 mV
Non-linearity (exact vs linear)-0.049975 %

Open this example in the calculator and change any input.

Formula

\(V_o = V_{ex}\,\frac{GF\,\varepsilon/4}{1 + GF\,\varepsilon/2}\ (\tfrac14), \quad V_o = V_{ex}\,\frac{GF\,\varepsilon}{2}\ (\tfrac12), \quad V_o = V_{ex}\, GF\,\varepsilon\ (\text{full})\)

Variables

Symbol Meaning SI unit
\(GF\) Gauge factor -
\(\varepsilon\) Strain -
\(V_{ex}\) Excitation voltage V
\(\text{bridge}\) Arrangement -
\(V_o\) Bridge output V
\(V_{lin}\) Linear approximation V
\(e_{nl}\) Non-linearity (exact vs linear) -

Method and standards

Bridge equations.

Where it is used

  • Stress measurement on structures.
  • Load cell and torque sensor design.

Common mistakes

  • Microstrain entered as strain.
  • Lead resistance ignored.

Assumptions and limits

  • Equal arms, ideal bridge.
  • Half and full bridge outputs assume the active gauges see equal and opposite strain, as in bending. With axial loading and Poisson gauges the output is smaller: \(GF\,\varepsilon(1+\nu)/4 \times V_{ex}\) for a half bridge and \(GF\,\varepsilon(1+\nu)/2 \times V_{ex}\) for a full bridge.

References

  • Wheatstone bridge with strain gauges
  • ΔR/R = GF ε

Questions and answers

What does 500 µε give in a quarter bridge at 5 V, GF 2?

1.2494 mV (linear 1.25 mV).

And a full bridge?

5 mV, four times more.

Why is the quarter bridge non-linear?

Only one arm changes, so the bridge current changes too.

Method and article reviewed by FireCAD engineering on 12 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.

Related calculators

Free engineering calculators: every page computes in SI and converts to your units. Results are for engineering estimation; verify critical designs against the referenced standards.

Rejoining the server...

Rejoin failed... trying again in seconds.

Failed to rejoin.
Please retry or reload the page.

The session has been paused by the server.

Failed to resume the session.
Please retry or reload the page.