FireCADCalc

Sampling: Nyquist Frequency and Alias Frequency

Nyquist frequency of a sampling rate, the frequency a signal appears at after sampling (alias), and the lowest sampling rate for a signal bandwidth.

Thermal power plantProcess steam and utilities

Inputs

Examples: 13 Hz sampled at 10 Hz50 Hz hum sampled at 60 Hz1 kHz tone at 44.1 kHz (no aliasing)

Results

The signal is above the Nyquist frequency: it appears at the alias frequency. Filter it out before sampling.

Nyquist frequency f_s / 230.000Hz
Apparent (alias) frequency10.000Hz
Lowest sampling rate for the bandwidth 2B50.000Hz

Download PDF CSV Link to this result Compare another case

Log in to save calculations to your dashboard.

Worked example

Example: 13 Hz sampled at 10 Hz. The inputs, in the units selected above:

InputValue
Sampling rate10.000 Hz
Signal frequency13.000 Hz
Highest frequency of interest2.0000 Hz

Applying the formula below gives:

ResultValue
Nyquist frequency f_s / 25.0000 Hz
Apparent (alias) frequency3.0000 Hz
Lowest sampling rate for the bandwidth 2B4.0000 Hz

Open this example in the calculator and change any input.

Formula

\(f_N = \frac{f_s}{2}, \quad f_a = |f - k f_s|,\ k = \text{round}(f/f_s), \quad f_{s,min} = 2B\)

Variables

Symbol Meaning SI unit
\(f_s\) Sampling rate 1/s
\(f\) Signal frequency 1/s
\(B\) Highest frequency of interest 1/s
\(f_N\) Nyquist frequency f_s / 2 1/s
\(f_a\) Apparent (alias) frequency 1/s
\(f_{s,min}\) Lowest sampling rate for the bandwidth 2B 1/s

Method and standards

Sampling theorem.

Where it is used

  • Data logging and PLC scan rates.
  • Vibration acquisition.

Common mistakes

  • No anti-aliasing filter.
  • Sampling exactly at 2B.

Assumptions and limits

  • Ideal sampling.

References

  • Nyquist–Shannon sampling theorem

Questions and answers

A 13 Hz signal sampled at 10 Hz appears at?

3 Hz.

What sampling rate for 2 Hz content?

At least 4 Hz; in practice 5 to 10 times the bandwidth.

Why does a PLC show a slow wave on a fast signal?

Aliasing: the scan rate is too slow for the signal.

Method and article reviewed by FireCAD engineering on 12 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.

Related calculators

Free engineering calculators: every page computes in SI and converts to your units. Results are for engineering estimation; verify critical designs against the referenced standards.

Rejoining the server...

Rejoin failed... trying again in seconds.

Failed to rejoin.
Please retry or reload the page.

The session has been paused by the server.

Failed to resume the session.
Please retry or reload the page.