Venturi Tube Flow Rate (ISO 5167-4)

Mass and volume flow through a classical venturi tube from throat and pipe diameters, differential pressure and density, with expansibility for gases.

Thermal power plantProcess steam and utilitiesRefinery and petrochemicalChemical and fertiliserISO 5167 (differential-pressure flow)PumpFan and blower

Inputs

Examples: Water, 100/200 mm, 25 kPa, C 0.995Air at 5 bar(a), 150/300 mm, 40 kPa, C 0.995Oil, 50/100 mm, 50 kPa, as-cast C 0.984

From ISO 5167-4 for your venturi construction, or from its calibration certificate.

Results

The Reynolds number is not checked (no viscosity input): make sure the flow lies in the ISO 5167-4 Reynolds range for your venturi construction, for which the discharge coefficient entered applies.

Diameter ratio d/D0.50000
Velocity of approach factor 1/√(1 − β⁴)1.0328
Expansibility factor1.0000
Mass flow66,229kg/h
Volume flow at inlet conditions77.917m³/h

Download PDF CSV Link to this result Compare another case

Log in to save calculations to your dashboard.

Worked example

Example: Water, 100/200 mm, 25 kPa, C 0.995. The inputs, in the units selected above:

InputValue
FluidLiquid (incompressible)
Throat diameter100.00 mm
Pipe (inlet) diameter200.00 mm
Differential pressure25.000 kPa
Density at the inlet tapping998.00 kg/m³
Inlet pressure, absolute (gas)5.0000 bar
Isentropic exponent (gas)1.4000 -
Discharge coefficient0.99500 -

Applying the formula below gives:

ResultValue
Diameter ratio d/D0.50000
Velocity of approach factor 1/√(1 − β⁴)1.0328
Expansibility factor1.0000
Mass flow205,249 kg/h
Volume flow at inlet conditions205.66 m³/h

Open this example in the calculator and change any input.

Formula

\(q_m = \frac{C\, \varepsilon}{\sqrt{1 - \beta^4}} \frac{\pi}{4} d^2 \sqrt{2\, \Delta p\, \rho_1}, \quad \beta = d/D\)

\(\varepsilon = \sqrt{\frac{\kappa \tau^{2/\kappa}}{\kappa - 1} \cdot \frac{1 - \beta^4}{1 - \beta^4 \tau^{2/\kappa}} \cdot \frac{1 - \tau^{(\kappa-1)/\kappa}}{1 - \tau}}, \quad \tau = \frac{p_1 - \Delta p}{p_1}\)

Variables

Symbol Meaning SI unit
\(\text{fluid}\) Fluid -
\(d\) Throat diameter m
\(D\) Pipe (inlet) diameter m
\(\Delta p\) Differential pressure Pa
\(\rho_1\) Density at the inlet tapping kg/m³
\(p_1\) Inlet pressure, absolute (gas) Pa
\(\kappa\) Isentropic exponent (gas) -
\(C\) Discharge coefficient -
\(\beta\) Diameter ratio d/D -
\(E\) Velocity of approach factor 1/√(1 − β⁴) -
\(\varepsilon\) Expansibility factor -
\(q_m\) Mass flow kg/s
\(q_V\) Volume flow at inlet conditions m³/s
\(\tau\) Pressure ratio (p₁ − Δp)/p₁ -

Method and standards

The differential-pressure flow equation of ISO 5167 with the isentropic expansibility used for venturi tubes and nozzles; the discharge coefficient is entered for your construction or from calibration.

Where it is used

  • Cooling water, feedwater and air flow measurement.
  • Checking a venturi's DP transmitter range.
  • Comparing venturi and orifice meters.

Common mistakes

  • Using the orifice expansibility formula for a venturi.
  • Using downstream density.
  • Using the throat diameter at the wrong temperature.

Assumptions and limits

  • Full pipe, steady flow; ISO 5167-4 limits on β and Reynolds number.
  • The discharge coefficient is entered, not computed, and there is no viscosity input, so the Reynolds number is not checked: confirm that the pipe Reynolds number lies in the range ISO 5167-4 gives for your construction (or in the calibration range), otherwise the entered C does not apply. β and the gas pressure ratio are checked.

References

  • ISO 5167-4 classical venturi tubes (method)

Questions and answers

What flow does a 100/200 mm venturi give at 25 kPa on water?

With C 0.995, 57.0 kg/s, about 205 m³/h.

How does a gas change it?

The expansibility factor: air at 5 bar(a) with 40 kPa drop has ε = 0.953, so the flow is 4.7 % below the liquid formula.

Why use a venturi instead of an orifice?

Much lower permanent pressure loss and less wear, at higher cost and length.

Method and article reviewed by FireCAD engineering on 12 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.

Related calculators

Free engineering calculators: every page computes in SI and converts to your units. Results are for engineering estimation; verify critical designs against the referenced standards.

Rejoining the server...

Rejoin failed... trying again in seconds.

Failed to rejoin.
Please retry or reload the page.

The session has been paused by the server.

Failed to resume the session.
Please retry or reload the page.