Individuals and Moving Range (I-MR) Control Chart

Centre line and control limits of an individuals (X) chart and a moving range chart from up to 12 readings, with the estimated sigma and points out of limits.

Inputs

Examples: Illustrative ten readings around 50Twelve readings with a shiftThree readings

Accepted: 3 to 12
Accepted: -1E+12 to 1E+12
Accepted: -1E+12 to 1E+12
Accepted: -1E+12 to 1E+12
Accepted: -1E+12 to 1E+12
Accepted: -1E+12 to 1E+12
Accepted: -1E+12 to 1E+12
Accepted: -1E+12 to 1E+12
Accepted: -1E+12 to 1E+12
Accepted: -1E+12 to 1E+12
Accepted: -1E+12 to 1E+12
Accepted: -1E+12 to 1E+12
Accepted: -1E+12 to 1E+12

Results

For individual readings the short-term sigma is estimated from the average moving range of successive pairs, σ̂ = MR̄/d₂ with d₂ = 2/√π ≈ 1.128 for ranges of two. The X chart limits are x̄ ± 3σ̂ (x̄ ± 2.66 MR̄) and the MR chart's upper limit is D₄MR̄ with D₄ = 1 + 3d₃/d₂ ≈ 3.267 (lower limit zero). Set limits from a stable period of at least 20 readings in practice; a dozen gives only a first look.

Centre line (mean)50.170
Mean moving range0.53333
Estimated sigma MR̄/d₂0.47265
Upper control limit (X)51.588
Lower control limit (X)48.752
Upper control limit (MR)1.7422
Readings outside the X limits0

Download PDF CSV Link to this result Compare another case

Log in to save calculations to your dashboard.

Worked example

Example: Illustrative ten readings around 50. The inputs, in the units selected above:

InputValue
Number of readings used (3–12)10.000 -
Value 150.200 -
Value 249.800 -
Value 350.500 -
Value 450.100 -
Value 549.600 -
Value 650.300 -
Value 750.900 -
Value 849.900 -
Value 950.000 -
Value 1050.400 -
Value 110 -
Value 120 -

Applying the formula below gives:

ResultValue
Centre line (mean)50.170
Mean moving range0.53333
Estimated sigma MR̄/d₂0.47265
Upper control limit (X)51.588
Lower control limit (X)48.752
Upper control limit (MR)1.7422
Readings outside the X limits0

Open this example in the calculator and change any input.

Formula

\(\hat\sigma = \frac{\overline{MR}}{d_2}, \quad UCL, LCL = \bar x \pm 3\hat\sigma, \quad UCL_{MR} = \left(1 + 3\frac{d_3}{d_2}\right)\overline{MR}\)

Variables

Symbol Meaning SI unit
\(n\) Number of readings used (3–12) -
\(x_{1}\) Value 1 -
\(x_{2}\) Value 2 -
\(x_{3}\) Value 3 -
\(x_{4}\) Value 4 -
\(x_{5}\) Value 5 -
\(x_{6}\) Value 6 -
\(x_{7}\) Value 7 -
\(x_{8}\) Value 8 -
\(x_{9}\) Value 9 -
\(x_{10}\) Value 10 -
\(x_{11}\) Value 11 -
\(x_{12}\) Value 12 -
\(\bar x\) Centre line (mean) -
\(\overline{MR}\) Mean moving range -
\(\hat\sigma\) Estimated sigma MR̄/d₂ -
\(UCL_X\) Upper control limit (X) -
\(LCL_X\) Lower control limit (X) -
\(UCL_{MR}\) Upper control limit (MR) -
\(n_{out}\) Readings outside the X limits -

Method and standards

I-MR chart.

Where it is used

  • Batch processes and slow measurements with one reading per subgroup.
  • Laboratory and utility data.

Common mistakes

  • Using the overall standard deviation for the limits.
  • Treating specification limits as control limits.

Assumptions and limits

  • Readings independent and roughly normal; d₂ and d₃ for subgroups of two.

References

  • Shewhart individuals and moving range chart

Questions and answers

Why use the moving range rather than the standard deviation?

It measures short-term variation only, so a drifting process does not widen its own limits.

How many readings are needed?

Twenty to twenty-five from a stable period is the usual minimum for trial limits.

What do the defaults represent?

Ten illustrative readings of a dimension around 50.

Method and article reviewed by FireCAD engineering on 17 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.

Sources

Montgomery, Introduction to Statistical Quality Control, 7th ed. (Wiley, 2013)

Related calculators

Free engineering calculators: every page computes in SI and converts to your units. Results are for engineering estimation; verify critical designs against the referenced standards.

Rejoining the server...

Rejoin failed... trying again in seconds.

Failed to rejoin.
Please retry or reload the page.

The session has been paused by the server.

Failed to resume the session.
Please retry or reload the page.