FireCADCalc

Colour Temperature in Mired and Mired Shift

Mired (micro reciprocal degree) values of two colour temperatures and the mired shift between them, used to choose correction filters and compare lamp colour.

Thermal power plantProcess steam and utilities

Inputs

Examples: Illustrative 3000 K to 5600 KTungsten 3200 K to daylight 5600 KDaylight to warm 6500 to 2700 K

Accepted: 726.85 to 19,727 °C
Accepted: 726.85 to 19,727 °C

Results

Mired = 10⁶/T. Equal mired steps look roughly equally different to the eye, which is why filters are rated in mired: a negative shift (blue filter) raises colour temperature.

Mired of the source312.50
Mired of the target178.57
Mired shift M₂ − M₁ (negative = bluer)-133.93
Temperature ratio1.7500

Download PDF CSV Link to this result Compare another case

Log in to save calculations to your dashboard.

Worked example

Example: Illustrative 3000 K to 5600 K. The inputs, in the units selected above:

InputValue
Source colour temperature2,726.8 °C
Target colour temperature5,326.9 °C

Applying the formula below gives:

ResultValue
Mired of the source333.33
Mired of the target178.57
Mired shift M₂ − M₁ (negative = bluer)-154.76
Temperature ratio1.8667

Open this example in the calculator and change any input.

Formula

\(M = \frac{10^6}{T}, \quad \Delta M = M_2 - M_1\)

Variables

Symbol Meaning SI unit
\(T_1\) Source colour temperature K
\(T_2\) Target colour temperature K
\(M_1\) Mired of the source -
\(M_2\) Mired of the target -
\(\Delta M\) Mired shift M₂ − M₁ (negative = bluer) -
\(T_2/T_1\) Temperature ratio -

Method and standards

Mired scale.

Where it is used

  • Photography, film and stage lighting.
  • Mixing lamp colours in buildings.

Common mistakes

  • Adding kelvin values of filters.
  • Confusing CCT with colour rendering.

Assumptions and limits

  • Black-body-like sources.

References

  • Reciprocal colour temperature
  • Mired scale of colour temperature

Questions and answers

Why use mired instead of kelvin?

Perceived colour change follows the reciprocal of temperature: 2,700 to 3,000 K is a bigger visible step than 6,000 to 6,500 K.

What shift turns tungsten into daylight?

From 3,200 K to 5,600 K is about −134 mired, the value of a full blue correction filter.

What do the defaults represent?

An illustrative warm 3,000 K source corrected towards 5,600 K daylight.

Method and article reviewed by FireCAD engineering on 17 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.

Related calculators

Free engineering calculators: every page computes in SI and converts to your units. Results are for engineering estimation; verify critical designs against the referenced standards.

Rejoining the server...

Rejoin failed... trying again in seconds.

Failed to rejoin.
Please retry or reload the page.

The session has been paused by the server.

Failed to resume the session.
Please retry or reload the page.