Worked example
Example: Illustrative 3000 K to 5600 K. The inputs, in the units selected above:
| Input | Value |
|---|---|
| Source colour temperature | 2,726.8 °C |
| Target colour temperature | 5,326.9 °C |
Applying the formula below gives:
| Result | Value |
|---|---|
| Mired of the source | 333.33 |
| Mired of the target | 178.57 |
| Mired shift M₂ − M₁ (negative = bluer) | -154.76 |
| Temperature ratio | 1.8667 |
Open this example in the calculator and change any input.
Formula
\(M = \frac{10^6}{T}, \quad \Delta M = M_2 - M_1\)
Variables
| Symbol | Meaning | SI unit |
|---|---|---|
| \(T_1\) | Source colour temperature | K |
| \(T_2\) | Target colour temperature | K |
| \(M_1\) | Mired of the source | - |
| \(M_2\) | Mired of the target | - |
| \(\Delta M\) | Mired shift M₂ − M₁ (negative = bluer) | - |
| \(T_2/T_1\) | Temperature ratio | - |
Method and standards
Mired scale.
Where it is used
- Photography, film and stage lighting.
- Mixing lamp colours in buildings.
Common mistakes
- Adding kelvin values of filters.
- Confusing CCT with colour rendering.
Assumptions and limits
- Black-body-like sources.
References
- Reciprocal colour temperature
- Mired scale of colour temperature
Questions and answers
Why use mired instead of kelvin?
Perceived colour change follows the reciprocal of temperature: 2,700 to 3,000 K is a bigger visible step than 6,000 to 6,500 K.
What shift turns tungsten into daylight?
From 3,200 K to 5,600 K is about −134 mired, the value of a full blue correction filter.
What do the defaults represent?
An illustrative warm 3,000 K source corrected towards 5,600 K daylight.
Method and article reviewed by FireCAD engineering on 17 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.