FireCADCalc

Beam Angle, Spot Diameter and Illuminance of a Spotlight

Spot diameter at a throw distance from a lamp's beam angle, the beam solid angle, mean luminous intensity and the illuminance in the spot.

Food, dairy and textile

Inputs

Examples: Illustrative 800 lm, 36 deg at 3 mNarrow 10 deg at 6 mWide flood 60 deg at 10 m

Accepted: 1 to 1,000,000
Accepted: 10 to 100 %
Accepted: 0.57296 to 171.89 °
Accepted: 0.1 to 500 m

Results

Beam angle is the full angle where intensity falls to 50 % of peak; the real centre intensity is higher than this mean. Use the maker's peak candela (CBCP) for accurate centre illuminance.

Spot diameter11.547m
Beam solid angle (sr)0.84179
Mean intensity in the beam (cd)20,195
Centre illuminance (I/d²)201.95lx
Average illuminance over the spot162.34lx

Download PDF CSV Link to this result Compare another case

Log in to save calculations to your dashboard.

Worked example

Example: Illustrative 800 lm, 36 deg at 3 m. The inputs, in the units selected above:

InputValue
Lamp luminous flux (lm)800.00 -
Share of flux inside the beam angle80.000 %
Beam angle (full)36.000 °
Throw distance3.0000 m

Applying the formula below gives:

ResultValue
Spot diameter1.9495 m
Beam solid angle (sr)0.30752
Mean intensity in the beam (cd)2,081.2
Centre illuminance (I/d²)231.24 lx
Average illuminance over the spot214.41 lx

Open this example in the calculator and change any input.

Formula

\(D = 2d\tan\frac\theta2, \quad \Omega = 2\pi\left(1 - \cos\frac\theta2\right), \quad I = \frac{\eta_b\Phi}{\Omega}\)

Variables

Symbol Meaning SI unit
\(\Phi\) Lamp luminous flux (lm) -
\(\eta_b\) Share of flux inside the beam angle -
\(\theta\) Beam angle (full) rad
\(d\) Throw distance m
\(D\) Spot diameter m
\(\Omega\) Beam solid angle (sr) -
\(I\) Mean intensity in the beam (cd) -
\(E_c\) Centre illuminance (I/d²) lx
\(E_{avg}\) Average illuminance over the spot lx

Method and standards

Beam geometry.

Where it is used

  • Display, stage and accent lighting.
  • Choosing beam angles for ceiling heights.

Common mistakes

  • Confusing beam angle with field angle.
  • Using total flux as if all were in the beam.

Assumptions and limits

  • Uniform intensity within the beam (mean value).

References

  • Cone geometry and solid angle
  • Lighting Handbook practice (lumen method, maintenance factor components)

Questions and answers

What does a 36° beam give at 3 m?

A spot just under 2 m across.

Why are narrow beams so bright?

The same flux is squeezed into a smaller solid angle, raising intensity and illuminance.

What do the defaults represent?

An illustrative 800 lm spotlight with a 36° beam holding 80 % of its flux, aimed 3 m away.

Method and article reviewed by FireCAD engineering on 17 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.

Related calculators

Free engineering calculators: every page computes in SI and converts to your units. Results are for engineering estimation; verify critical designs against the referenced standards.

Rejoining the server...

Rejoin failed... trying again in seconds.

Failed to rejoin.
Please retry or reload the page.

The session has been paused by the server.

Failed to resume the session.
Please retry or reload the page.