Worked example
Example: Illustrative 96 cells, 50 A. The inputs, in the units selected above:
| Input | Value |
|---|---|
| Cell current (positive discharge) | 50.000 A |
| Cell internal resistance | 0.002000 Ω |
| Cell temperature | 25.000 °C |
| Entropic coefficient of open-circuit voltage (V/K) | -1.0000e-04 - |
| Cells in the pack | 96.000 - |
| Pack mass | 300.00 kg |
| Pack specific heat | 1.0000 kJ/(kg·K) |
Applying the formula below gives:
| Result | Value |
|---|---|
| Joule heat per cell | 0.005000 kW |
| Reversible heat per cell | 0.001491 kW |
| Total heat per cell | 0.006491 kW |
| Pack heat | 0.62311 kW |
| Adiabatic temperature rise rate | 0.002077 K/s |
Open this example in the calculator and change any input.
Formula
\(\dot Q = I^2R - IT\frac{dU}{dT}, \quad \frac{dT}{dt} = \frac{n\dot Q}{mc_p}\)
Variables
| Symbol | Meaning | SI unit |
|---|---|---|
| \(I\) | Cell current (positive discharge) | A |
| \(R\) | Cell internal resistance | Ω |
| \(T\) | Cell temperature | K |
| \(dU/dT\) | Entropic coefficient of open-circuit voltage (V/K) | - |
| \(n\) | Cells in the pack | - |
| \(m\) | Pack mass | kg |
| \(c_p\) | Pack specific heat | J/(kg·K) |
| \(\dot Q_{irr}\) | Joule heat per cell | W |
| \(\dot Q_{rev}\) | Reversible heat per cell | W |
| \(\dot Q\) | Total heat per cell | W |
| \(\dot Q_{pack}\) | Pack heat | W |
| \(dT/dt\) | Adiabatic temperature rise rate | K/s |
Method and standards
Battery heat.
Where it is used
- Thermal management design for EVs and stationary packs.
- Cooling system sizing.
Common mistakes
- Ignoring internal resistance growth at low temperature.
- Assuming the reversible heat is always positive.
Assumptions and limits
- Uniform temperature; constant properties.
References
- Bernardi battery heat generation
Questions and answers
Why does fast charging heat batteries?
Joule heat grows with the square of current; doubling the charging rate quadruples it.
What is reversible heat?
Heat from the entropy change of the cell reaction; it can cool or heat the cell depending on direction and chemistry.
What do the defaults represent?
An illustrative pack of 96 cells of 2 mΩ at 50 A and 25 °C with dU/dT −0.1 mV/K, 300 kg and 1,000 J/(kg·K).
Method and article reviewed by FireCAD engineering on 17 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.