FireCADCalc

Two-Span Continuous Beam (Three-Moment Equation)

Support moment, reactions and maximum span moments of a two-span continuous beam with uniform loads on each span, by Clapeyron's three-moment equation.

Thermal power plantProcess steam and utilitiesSugar mill and cogenerationRefinery and petrochemicalChemical and fertiliserPulp and paper

Inputs

Examples: 6 m and 8 m spans, 20 kN/mEqual 5 m spans, 30 and 10 kN/m

Results

Constant EI, simple end supports, no settlement. For equal spans and loads M_B = wL²/8 and the middle reaction is 1.25wL.

Moment at the middle support (hogging)130.00kN·m
End reaction A38.333kN
Middle reaction B177.92kN
End reaction C63.750kN
Maximum sagging moment, span 136.736kN·m
Maximum sagging moment, span 2101.60kN·m

Download PDF CSV Link to this result Compare another case

Log in to save calculations to your dashboard.

Worked example

Example: 6 m and 8 m spans, 20 kN/m. The inputs, in the units selected above:

InputValue
Span 16.0000 m
Span 28.0000 m
Uniform load on span 120.000 kN/m
Uniform load on span 220.000 kN/m

Applying the formula below gives:

ResultValue
Moment at the middle support (hogging)130.00 kN·m
End reaction A38.333 kN
Middle reaction B177.92 kN
End reaction C63.750 kN
Maximum sagging moment, span 136.736 kN·m
Maximum sagging moment, span 2101.60 kN·m

Open this example in the calculator and change any input.

Formula

\(M_B = \frac{w_1L_1^3 + w_2L_2^3}{8(L_1 + L_2)}, \quad R_A = \frac{w_1L_1}{2} - \frac{M_B}{L_1}\)

Variables

Symbol Meaning SI unit
\(L_1\) Span 1 m
\(L_2\) Span 2 m
\(w_1\) Uniform load on span 1 N/m
\(w_2\) Uniform load on span 2 N/m
\(M_B\) Moment at the middle support (hogging) N·m
\(R_A\) End reaction A N
\(R_B\) Middle reaction B N
\(R_C\) End reaction C N
\(M_1\) Maximum sagging moment, span 1 N·m
\(M_2\) Maximum sagging moment, span 2 N·m

Method and standards

Three-moment equation with M_A = M_C = 0.

Where it is used

  • Continuous purlins, pipe racks and floor beams.
  • Checking two-span pipe supports.

Common mistakes

  • Using simply supported moments for continuous beams.
  • Ignoring the hogging moment at the support.

Assumptions and limits

  • Both spans fully loaded at once. The largest sagging moment in a span comes from pattern loading (imposed load on that span only, dead load on both), which this page does not check; for floor beams with large imposed loads, run the case with the other span's load reduced to dead load only.

  • Constant EI; uniform loads; rigid supports.

References

  • Clapeyron's three-moment equation (Timoshenko and Young, Theory of Structures, 2nd ed. (McGraw-Hill))

Questions and answers

Why is the middle reaction more than half the load?

Continuity makes the beam hog over the support, drawing load towards it: 1.25wL for equal spans.

Is continuity always better?

Span moments fall, but the support moment becomes the largest; the section there must take it.

What do the defaults represent?

Spans of 6 and 8 m with 20 kN/m on both.

Method and article reviewed by FireCAD engineering on 13 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.

Related calculators

Free engineering calculators: every page computes in SI and converts to your units. Results are for engineering estimation; verify critical designs against the referenced standards.

Rejoining the server...

Rejoin failed... trying again in seconds.

Failed to rejoin.
Please retry or reload the page.

The session has been paused by the server.

Failed to resume the session.
Please retry or reload the page.