Worked example
Example: 6 m and 8 m spans, 20 kN/m. The inputs, in the units selected above:
| Input | Value |
|---|---|
| Span 1 | 6.0000 m |
| Span 2 | 8.0000 m |
| Uniform load on span 1 | 20.000 kN/m |
| Uniform load on span 2 | 20.000 kN/m |
Applying the formula below gives:
| Result | Value |
|---|---|
| Moment at the middle support (hogging) | 130.00 kN·m |
| End reaction A | 38.333 kN |
| Middle reaction B | 177.92 kN |
| End reaction C | 63.750 kN |
| Maximum sagging moment, span 1 | 36.736 kN·m |
| Maximum sagging moment, span 2 | 101.60 kN·m |
Open this example in the calculator and change any input.
Formula
\(M_B = \frac{w_1L_1^3 + w_2L_2^3}{8(L_1 + L_2)}, \quad R_A = \frac{w_1L_1}{2} - \frac{M_B}{L_1}\)
Variables
| Symbol | Meaning | SI unit |
|---|---|---|
| \(L_1\) | Span 1 | m |
| \(L_2\) | Span 2 | m |
| \(w_1\) | Uniform load on span 1 | N/m |
| \(w_2\) | Uniform load on span 2 | N/m |
| \(M_B\) | Moment at the middle support (hogging) | N·m |
| \(R_A\) | End reaction A | N |
| \(R_B\) | Middle reaction B | N |
| \(R_C\) | End reaction C | N |
| \(M_1\) | Maximum sagging moment, span 1 | N·m |
| \(M_2\) | Maximum sagging moment, span 2 | N·m |
Method and standards
Three-moment equation with M_A = M_C = 0.
Where it is used
- Continuous purlins, pipe racks and floor beams.
- Checking two-span pipe supports.
Common mistakes
- Using simply supported moments for continuous beams.
- Ignoring the hogging moment at the support.
Assumptions and limits
Both spans fully loaded at once. The largest sagging moment in a span comes from pattern loading (imposed load on that span only, dead load on both), which this page does not check; for floor beams with large imposed loads, run the case with the other span's load reduced to dead load only.
Constant EI; uniform loads; rigid supports.
References
- Clapeyron's three-moment equation (Timoshenko and Young, Theory of Structures, 2nd ed. (McGraw-Hill))
Questions and answers
Why is the middle reaction more than half the load?
Continuity makes the beam hog over the support, drawing load towards it: 1.25wL for equal spans.
Is continuity always better?
Span moments fall, but the support moment becomes the largest; the section there must take it.
What do the defaults represent?
Spans of 6 and 8 m with 20 kN/m on both.
Method and article reviewed by FireCAD engineering on 13 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.