Worked example
Example: 40 m2 of 600 x 600. The inputs, in the units selected above:
| Input | Value |
|---|---|
| Area to tile | 40.000 m² |
| Tile length | 600.00 mm |
| Tile width | 600.00 mm |
| Joint width | 3.0000 mm |
| Wastage for cutting and breakage | 8.0000 % |
| Tiles per box | 4.0000 - |
| Bed thickness (mortar or adhesive) | 20.000 mm |
Applying the formula below gives:
| Result | Value |
|---|---|
| Tiles needed | 119.00 |
| Boxes (rounded up) | 30.000 |
| Bed volume | 0.80000 m³ |
Open this example in the calculator and change any input.
Formula
\(N = \frac{A}{(l + j)(w + j)}(1 + k_w)\)
Variables
| Symbol | Meaning | SI unit |
|---|---|---|
| \(A\) | Area to tile | m² |
| \(l\) | Tile length | m |
| \(w\) | Tile width | m |
| \(j\) | Joint width | m |
| \(k_w\) | Wastage for cutting and breakage | - |
| \(n_b\) | Tiles per box | - |
| \(t_b\) | Bed thickness (mortar or adhesive) | m |
| \(N\) | Tiles needed | - |
| \(N_b\) | Boxes (rounded up) | - |
| \(V_b\) | Bed volume | m³ |
Method and standards
Area divided by tile pitch area.
Where it is used
- Flooring and wall cladding estimates.
- Purchase.
Common mistakes
- No wastage.
- Ignoring joint width for large formats.
Assumptions and limits
- Rectangular tiles.
References
- Tiles = area / ((l + j)(w + j)) (Common site practice (quantity estimating))
Questions and answers
40 m² with 600 × 600 tiles, 3 mm joints, 8 % wastage?
119 tiles, 30 boxes of 4.
How much wastage?
More for diagonal patterns and small rooms (10–15 %).
Skirting?
Add the perimeter length separately.
Method and article reviewed by FireCAD engineering on 12 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.