FireCADCalc

Boom Sprayer Calibration: Nozzle Flow and Tank Coverage

Nozzle output needed for an application rate at a forward speed and nozzle spacing, the area covered by one tank and the chemical per tank.

Inputs

Examples: Illustrative 24-nozzle boomLow volume, fastKnapsack walk

Accepted: 10 to 2,000
Accepted: 0.36 to 36 km/h
Accepted: 100 to 5,000 mm
Accepted: 5 to 50,000 L
Accepted: 0 to 100
Accepted: 1 to 200

Results

Each nozzle sprays a strip as wide as the nozzle spacing; at speed v it covers w·v of ground per second, so it must deliver R·w·v. In practical units, q (L/min) = R (L/ha) × v (km/h) × w (m)/600. Measure each nozzle's output into a jug for a minute and replace any more than 10 % off. The tank covers its volume over the rate, which sets the product to add per tank.

Nozzle output needed1.2500L/min
Boom output45.000L/min
Area per tank6.6667ha
Product per tank (same unit as the dose)3.3333

Download PDF CSV Link to this result Compare another case

Log in to save calculations to your dashboard.

Worked example

Example: Illustrative 24-nozzle boom. The inputs, in the units selected above:

InputValue
Spray volume rate (litres per hectare)300.00 -
Forward speed6.0000 km/h
Nozzle spacing on the boom (or swath per nozzle)500.00 mm
Tank volume600.00 L
Product dose per hectare1.5000 -
Nozzles on the boom24.000 -

Applying the formula below gives:

ResultValue
Nozzle output needed1.5000 L/min
Boom output36.000 L/min
Area per tank2.0000 ha
Product per tank (same unit as the dose)3.0000

Open this example in the calculator and change any input.

Formula

\(q = R\,v\,w\ \ \left(\text{L/min} = \frac{R[\text{L/ha}]\,v[\text{km/h}]\,w[\text{m}]}{600}\right), \quad A_t = \frac{V_t}{R}\)

Variables

Symbol Meaning SI unit
\(R\) Spray volume rate (litres per hectare) -
\(v\) Forward speed m/s
\(w\) Nozzle spacing on the boom (or swath per nozzle) m
\(V_t\) Tank volume m³
\(D\) Product dose per hectare -
\(n\) Nozzles on the boom -
\(q\) Nozzle output needed m³/s
\(Q\) Boom output m³/s
\(A_t\) Area per tank m²
\(D_t\) Product per tank (same unit as the dose) -

Method and standards

Sprayer calibration.

Where it is used

  • Pesticide and liquid fertiliser application.
  • Checking worn nozzles.

Common mistakes

  • Changing speed without changing pressure or nozzles.
  • Using the boom width instead of nozzle spacing.

Assumptions and limits

  • Steady speed; uniform nozzles.

References

  • Sprayer calibration: q = R v w / 600 (L/min, L/ha, km/h, m)

Questions and answers

What nozzle output gives 300 L/ha at 6 km/h with 50 cm spacing?

1.5 L/min per nozzle.

How much product per tank?

The dose per hectare times the area one tank covers: 600 L at 300 L/ha covers 2 ha.

What do the defaults represent?

An illustrative boom of 24 nozzles 50 cm apart at 6 km/h, 300 L/ha, 600 L tank, 1.5 L of product per hectare.

Method and article reviewed by FireCAD engineering on 17 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.

Related calculators

Free engineering calculators: every page computes in SI and converts to your units. Results are for engineering estimation; verify critical designs against the referenced standards.

Rejoining the server...

Rejoin failed... trying again in seconds.

Failed to rejoin.
Please retry or reload the page.

The session has been paused by the server.

Failed to resume the session.
Please retry or reload the page.