FireCADCalc

Seepage from a Flow Net (Under a Dam or Sheet Pile)

Seepage per metre length under a dam, weir or sheet pile from permeability, head difference and the numbers of flow channels and equipotential drops of a flow net.

Inputs

Examples: Weir on silty sandSheet pile cofferdam

Results

The critical gradient i_c is γ'/γw, about 1 for most soils.

Seepage per metre2.5920m³/(d·m)
Total seepage77.760m³/d
Exit gradient (H/N_d)/l_e0.62500
Safety against piping i_c/i_e1.5200

Download PDF CSV Link to this result Compare another case

Log in to save calculations to your dashboard.

Worked example

Example: Weir on silty sand. The inputs, in the units selected above:

InputValue
Coefficient of permeability5.0000e-06 m/s
Head difference upstream to downstream6.0000 m
Number of flow channels4.0000 -
Number of equipotential drops12.000 -
Length of the structure50.000 m
Size of the last square at the exit1.2000 m
Submerged to water unit weight ratio1.0000 -

Applying the formula below gives:

ResultValue
Seepage per metre0.86400 m³/(d·m)
Total seepage43.200 m³/d
Exit gradient (H/N_d)/l_e0.41667
Safety against piping i_c/i_e2.4000

Open this example in the calculator and change any input.

Formula

\(q = k H \frac{N_f}{N_d}, \quad i_e = \frac{H/N_d}{l_e}, \quad FS = \frac{\gamma'/\gamma_w}{i_e}\)

Variables

Symbol Meaning SI unit
\(k\) Coefficient of permeability m/s
\(H\) Head difference upstream to downstream m
\(N_f\) Number of flow channels -
\(N_d\) Number of equipotential drops -
\(B\) Length of the structure m
\(l_e\) Size of the last square at the exit m
\(\gamma'/\gamma_w\) Submerged to water unit weight ratio -
\(q\) Seepage per metre m³/(s·m)
\(Q\) Total seepage m³/s
\(i_e\) Exit gradient (H/N_d)/l_e -
\(FS\) Safety against piping i_c/i_e -

Method and standards

Flow net theory.

Where it is used

  • Seepage under weirs, cofferdams and pond bunds.
  • Piping checks.

Common mistakes

  • Counting lines instead of channels.
  • Ignoring anisotropy.

Assumptions and limits

  • Isotropic, steady flow. With zero head the piping safety factor is not shown.

References

  • Flow net seepage q = k H N_f/N_d; critical gradient γ'/γ_w (Das; Craig)

Questions and answers

k 5e-6, 6 m head, 4 channels, 12 drops?

0.86 m³/day per metre; exit gradient 0.42.

Why squares?

A flow net of curvilinear squares makes the formula exact for isotropic soil.

Anisotropic soil?

Use √(kₓk_z) on a transformed section.

Method and article reviewed by FireCAD engineering on 12 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.

Related calculators

Free engineering calculators: every page computes in SI and converts to your units. Results are for engineering estimation; verify critical designs against the referenced standards.

Rejoining the server...

Rejoin failed... trying again in seconds.

Failed to rejoin.
Please retry or reload the page.

The session has been paused by the server.

Failed to resume the session.
Please retry or reload the page.