FireCADCalc

Fresh Concrete Temperature from Ingredient Temperatures

Temperature of fresh concrete from the masses and temperatures of aggregates, cement, mixing water and aggregate water, with ice as an option.

Thermal power plantProcess steam and utilitiesSugar mill and cogenerationRefinery and petrochemicalChemical and fertiliserPulp and paper

Inputs

Examples: Summer batch, no iceSame batch with 60 kg ice

Results

ACI 305 / 306 mixture formula with specific heat of solids 0.22 of water's and latent heat of ice 80 cal/g (ice at 0 °C, fully melted). Many specifications limit placing temperature to about 32–35 °C.

Fresh concrete temperature23.938°C
Cooling from melting the ice (latent term only)7.2289K

Download PDF CSV Link to this result Compare another case

Log in to save calculations to your dashboard.

Worked example

Example: Summer batch, no ice. The inputs, in the units selected above:

InputValue
Aggregate mass (dry)1,850.0 kg
Aggregate temperature35.000 °C
Cement mass350.00 kg
Cement temperature50.000 °C
Mixing water mass (excluding ice)140.00 kg
Mixing water temperature15.000 °C
Free water on aggregates40.000 kg
Ice replacing part of the mixing water0 kg

Applying the formula below gives:

ResultValue
Fresh concrete temperature32.523 °C
Cooling from melting the ice (latent term only)0 K

Open this example in the calculator and change any input.

Formula

\(T = \frac{0.22(T_aW_a + T_cW_c) + T_wW_w + T_aW_{wa} - 80W_i}{0.22(W_a + W_c) + W_w + W_{wa} + W_i}\)

Variables

Symbol Meaning SI unit
\(W_a\) Aggregate mass (dry) kg
\(T_a\) Aggregate temperature K
\(W_c\) Cement mass kg
\(T_c\) Cement temperature K
\(W_w\) Mixing water mass (excluding ice) kg
\(T_w\) Mixing water temperature K
\(W_{wa}\) Free water on aggregates kg
\(W_i\) Ice replacing part of the mixing water kg
\(T\) Fresh concrete temperature K
\(\Delta T_{ice}\) Cooling from melting the ice (latent term only) K

Method and standards

Heat balance (°C, kg).

Where it is used

  • Hot-weather concreting in Indian summers.
  • Mass concrete for foundations.

Common mistakes

  • Forgetting aggregate free water.
  • Counting ice also as mixing water.

Assumptions and limits

  • Ice at 0 °C, fully melted; a result below 0 °C (ice cannot all melt) is flagged.
  • ΔT_ice is the latent term 80 W_i over the heat-capacity sum: the cooling against the same batch with the ice's melt water at 0 °C, not against the ice replaced by mixing water at T_w.

References

  • ACI 305R (hot weather concreting) fresh concrete temperature equation

Questions and answers

Which ingredient matters most?

Aggregates, because of their mass; cooling them (shade, sprinkling) or the water gives the biggest effect per rupee.

How much does ice help?

Each kilogram of ice absorbs 80 kcal melting, roughly four to five times chilled water's effect.

What do the defaults represent?

A 1 m³ batch with sun-warmed aggregate and cement and cool mixing water, no ice.

Method and article reviewed by FireCAD engineering on 13 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.

Related calculators

Free engineering calculators: every page computes in SI and converts to your units. Results are for engineering estimation; verify critical designs against the referenced standards.

Rejoining the server...

Rejoin failed... trying again in seconds.

Failed to rejoin.
Please retry or reload the page.

The session has been paused by the server.

Failed to resume the session.
Please retry or reload the page.