FireCADCalc

Concrete Maturity and Equivalent Age (Nurse–Saul)

Temperature–time factor (maturity) of concrete from up to four curing periods by the Nurse–Saul function, and the equivalent age at a reference temperature (20 °C by default) for strength estimation.

Thermal power plantProcess steam and utilitiesSugar mill and cogenerationRefinery and petrochemicalChemical and fertiliserPulp and paper

Inputs

Examples: A week at 15–25 °C, datum −10 °CCold weather: 5 °C then 2 °C, three days

Results

Nurse–Saul maturity M = Σ(T − T₀)Δt with datum −10 °C (or the mix's own). Strength comes from the mix's own strength–maturity calibration curve (ASTM C1074).

Maturity5,400.0°C·h
Equivalent age at the reference temperature180.00h
Actual age168.00h

Download PDF CSV Link to this result Compare another case

Log in to save calculations to your dashboard.

Worked example

Example: A week at 15–25 °C, datum −10 °C. The inputs, in the units selected above:

InputValue
Datum temperature-10.000 °C
Period 1 mean temperature15.000 °C
Period 1 duration24.000 h
Period 2 mean temperature20.000 °C
Period 2 duration48.000 h
Period 3 mean temperature25.000 °C
Period 3 duration96.000 h
Period 4 mean temperature10.000 °C
Period 4 duration0 h
Reference temperature20.000 °C

Applying the formula below gives:

ResultValue
Maturity5,400.0 °C·h
Equivalent age at the reference temperature180.00 h
Actual age168.00 h

Open this example in the calculator and change any input.

Formula

\(M = \sum \max(T - T_0,\,0)\,\Delta t, \quad t_e = \frac{M}{T_r - T_0}\)

Variables

Symbol Meaning SI unit
\(T_0\) Datum temperature K
\(T_1\) Period 1 mean temperature K
\(\Delta t_1\) Period 1 duration s
\(T_2\) Period 2 mean temperature K
\(\Delta t_2\) Period 2 duration s
\(T_3\) Period 3 mean temperature K
\(\Delta t_3\) Period 3 duration s
\(T_4\) Period 4 mean temperature K
\(\Delta t_4\) Period 4 duration s
\(T_r\) Reference temperature K
\(M\) Maturity (°C·h) -
\(t_e\) Equivalent age at the reference temperature s
\(t\) Actual age s

Method and standards

Nurse–Saul function.

Where it is used

  • Formwork stripping and post-tensioning times.
  • Cold-weather concreting.

Common mistakes

  • Using the wrong datum.
  • Skipping the mix calibration curve.

Assumptions and limits

  • Mean temperatures over each period; a period colder than the datum adds nothing (it is not counted as negative maturity).
  • Maturity is always in °C·h, whatever the unit system.

References

  • Nurse–Saul maturity function (ASTM C1074 principle; Neville, Properties of Concrete, ch. 6)

Questions and answers

Why does temperature matter?

Cement hydration speeds up when warm; concrete cured cold gains strength slowly.

When is formwork safe to strike?

When the maturity reaches the value at which the calibrated mix has the needed strength.

What do the defaults represent?

A week of curing at 15–25 °C with a −10 °C datum.

Method and article reviewed by FireCAD engineering on 13 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.

Related calculators

Free engineering calculators: every page computes in SI and converts to your units. Results are for engineering estimation; verify critical designs against the referenced standards.

Rejoining the server...

Rejoin failed... trying again in seconds.

Failed to rejoin.
Please retry or reload the page.

The session has been paused by the server.

Failed to resume the session.
Please retry or reload the page.