Worked example
Example: Salt water, 50 g NaCl per kg, 1 atm. The inputs, in the units selected above:
| Input | Value |
|---|---|
| Pressure (absolute) | 1.0132 bar |
| Solute per kg of water | 0.050000 kg/kg |
| Molar mass of the solute | 58.440 kg/kmol |
| van 't Hoff factor (ions or particles per formula unit) | 2.0000 - |
Applying the formula below gives:
| Result | Value |
|---|---|
| Molality of the solute | 0.85558 mol/kg |
| Boiling point of pure water at the pressure | 99.974 °C |
| Ebullioscopic constant R T_b² / h_fg (K·kg/mol) | 0.51298 |
| Boiling point elevation i K_b b | 0.87778 K |
| Boiling point of the solution | 100.85 °C |
Open this example in the calculator and change any input.
Formula
\(b = \frac{w}{M_s}, \quad K_b = \frac{R\, T_b^2}{h_{fg}}\)
\(\Delta T_b = i\, K_b\, b\)
Variables
| Symbol | Meaning | SI unit |
|---|---|---|
| \(p\) | Pressure (absolute) | Pa |
| \(w\) | Solute per kg of water | kg/kg |
| \(M_s\) | Molar mass of the solute | kg/kmol |
| \(i\) | van 't Hoff factor (ions or particles per formula unit) | - |
| \(b\) | Molality of the solute | mol/kg |
| \(T_b\) | Boiling point of pure water at the pressure | K |
| \(K_b\) | Ebullioscopic constant R T_b² / h_fg (K·kg/mol) | - |
| \(\Delta T_b\) | Boiling point elevation i K_b b | K |
| \(T\) | Boiling point of the solution | K |
Method and standards
Dilute-solution limit of Raoult's law combined with the Clausius–Clapeyron equation; T_b and h_fg of water from IF97.
Where it is used
- Evaporator design.
- Brine and salt solutions.
- Chemistry examinations.
Common mistakes
- Using molarity instead of molality.
- Forgetting the van 't Hoff factor.
- Applying to concentrated liquors.
Assumptions and limits
- Dilute ideal solution, non-volatile solute.
References
- Ideal dilute solution (Raoult and Clausius–Clapeyron)
- IAPWS-IF97 (water and steam)
Questions and answers
How much does 50 g of salt per kg of water raise the boiling point?
Molality 0.856, van 't Hoff factor 2: ΔT = 2 × 0.513 × 0.856 = 0.88 K.
Where does 0.513 come from?
K_b = R T_b² / h_fg: 8.314 × 373.12² / 2 256 400 = 0.513 K·kg/mol at 1 atm.
Why does it matter in evaporators?
The boiling point rise reduces the temperature difference available, and must be added to the vapour temperature.
Method and article reviewed by FireCAD engineering on 12 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.