Worked example
Example: Acetate 0.1/0.15 M. The inputs, in the units selected above:
| Input | Value |
|---|---|
| pKa of the weak acid | 4.7600 - |
| Weak acid concentration | 0.10000 mol/L |
| Conjugate base concentration | 0.15000 mol/L |
| Target pH | 5.0000 - |
Applying the formula below gives:
| Result | Value |
|---|---|
| Buffer pH | 4.9361 |
| Ratio needed for the target pH | 1.7378 |
Open this example in the calculator and change any input.
Formula
\(pH = pK_a + \log_{10}\frac{[A^-]}{[HA]}\)
Variables
| Symbol | Meaning | SI unit |
|---|---|---|
| \(pK_a\) | pKa of the weak acid | - |
| \([HA]\) | Weak acid concentration | mol/m³ |
| \([A^-]\) | Conjugate base concentration | mol/m³ |
| \(pH_t\) | Target pH | - |
| \(pH\) | Buffer pH | - |
| \([A^-]/[HA]\) | Ratio needed for the target pH | - |
Method and standards
Henderson–Hasselbalch.
Where it is used
- Laboratory buffers for water analysis.
- Process pH control.
Common mistakes
- Using it for strong acids.
- pKa at the wrong temperature.
Assumptions and limits
- Dilute ideal solution. Notes appear when the buffer or target pH is more than one unit from the pKa.
References
- Henderson–Hasselbalch pH = pKa + log([A⁻]/[HA])
Questions and answers
Acetic acid 0.1 M with acetate 0.15 M?
pH 4.94.
For pH 5.0?
Base-to-acid ratio 1.74.
Why within one pH unit?
Outside it the buffer has little capacity and the approximation weakens.
Method and article reviewed by FireCAD engineering on 12 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.